Latest revision | Your text | ||
Line 73: | Line 73: | ||
|140404|| Overvoltage. [[HV DC bus]] exceeded the limit defined by {{param|FOV}} || Increase {{param|FOV}} or reduce supply voltage | |140404|| Overvoltage. [[HV DC bus]] exceeded the limit defined by {{param|FOV}} || Increase {{param|FOV}} or reduce supply voltage | ||
|- | |- | ||
− | |140405|| Undervoltage. [[HV DC bus]] was under the limit defined by {{param|FUV}} || Decrease {{param|FUV}} or increase supply voltage and ensure that PSU is capable of supplying demanded current surges without droop | + | |140405|| Undervoltage. [[HV DC bus]] was under the limit defined by {{param|FUV}} || Decrease {{param|FUV}} or increase supply voltage and ensure that PSU is capable of supplying demanded current surges without droop |
|- | |- | ||
|140406|| Overtemperature || Enhance drive cooling or reduce drive current limits | |140406|| Overtemperature || Enhance drive cooling or reduce drive current limits | ||
Line 205: | Line 205: | ||
|Contact Granite Devices and let us know how to repeat the error | |Contact Granite Devices and let us know how to repeat the error | ||
|} | |} | ||
− | |||
− | |||
− | |||
− |