This page supports semantic in-text annotations (e.g. "[[Is specified as::World Heritage Site]]") to build structured and queryable content provided by Semantic MediaWiki. For a comprehensive description on how to use annotations or the #ask parser function, please have a look at the getting started, in-text annotation, or inline queries help page.

Latest revision Your text
Line 1: Line 1:
{{SetGranityTabPageTitle|Connect}}[[File:granityconnect.png|thumb]]
+
This dialog serves following purposes:
This tab serves following purposes:
+
 
* Connecting and disconnecting to a drive
 
* Connecting and disconnecting to a drive
 
* Loading and saving settings
 
* Loading and saving settings
Line 12: Line 11:
  
 
Minimum requirements for connection:
 
Minimum requirements for connection:
* [[Argon]] or [[IONI]] motor drives
+
* [[Argon (servo drive)]]  
 
* 24VDC regulated power supply
 
* 24VDC regulated power supply
 
* [[SimpleMotion V2 compatible communication interface device]] (such as [[SimpleMotion V2 USB adapter]])
 
* [[SimpleMotion V2 compatible communication interface device]] (such as [[SimpleMotion V2 USB adapter]])
Line 18: Line 17:
  
 
===Establishing connection===
 
===Establishing connection===
====Argon====
 
 
# Connect PE of [[Argon_wiring#J3_24V_power_and_motor_brake_port|J4 connector]] to protective earth. After that wire 24 VDC power supply to Argon's [[Argon_wiring#J3_24V_power_and_motor_brake_port|J3 connector]], however do not power up yet.
 
# Connect PE of [[Argon_wiring#J3_24V_power_and_motor_brake_port|J4 connector]] to protective earth. After that wire 24 VDC power supply to Argon's [[Argon_wiring#J3_24V_power_and_motor_brake_port|J3 connector]], however do not power up yet.
 
# [[Setting device bus address|Set drive address]] to give an bus address to the device.
 
# [[Setting device bus address|Set drive address]] to give an bus address to the device.
# Connect Argon J2 (any of two ports) connector to [[SimpleMotion V2 USB adapter]] with a straight Ethernet cable and plug USB adapter to computer.
+
# Connect Argon J2.1 connector to [[SimpleMotion V2 USB adapter]] with a straight Ethernet cable and plug USB adapter to computer.
 
# Power up the 24 VDC power. Some leds should start blinking at the drive (specifily LD3 and/or LD4).
 
# Power up the 24 VDC power. Some leds should start blinking at the drive (specifily LD3 and/or LD4).
 
# Launch Granity software and:
 
# Launch Granity software and:
 
##Go to Connect tab
 
##Go to Connect tab
##Ensure that SM V2 USB adapter is selected from dropdown list called ''Communication interface device''
+
##Ensure that SM V2 USB adapter is selected from drowdown list called ''Communication interface device''
##Click ''Connect to drive''
+
##Once list of connected drives pop up, select the one you connected and click ''Open''
+
====IONICUBE====
+
# Wire up IONICUBE logic power (24V) supply.
+
# Connect IONICUBE connector X1 (any of two ports) connector to [[SimpleMotion V2 USB adapter]] with a straight Ethernet cable and plug USB adapter to  computer.
+
#Make sure that SM bus termination is set on.
+
#*IONICUBE 4 axis board rev. 007: insert jumper to JP10 position 1 (see image [[IONI & IONICUBE user guide/Making the first Granity connection|here]]),
+
#*IONICUBE 4 axis board rev. 009 and higher: set the switch S1 position 1 to ON (see image [[IONI & IONICUBE user guide/Making the first Granity connection|here]]), and
+
#*IONICUBE 1X, set DIP switch S1 position 1 on).
+
# Power up the 24 VDC power. Some leds should start blinking at the drive.
+
# Launch Granity software and:
+
##Go to Connect tab
+
##Ensure that SM V2 USB adapter is selected from dropdown list called ''Communication interface device''
+
 
##Click ''Connect to drive''
 
##Click ''Connect to drive''
 
##Once list of connected drives pop up, select the one you connected and click ''Open''
 
##Once list of connected drives pop up, select the one you connected and click ''Open''
  
 
Now if everything has gone well, you should see information like drive model and serial number on the Connect tab. Connection has been successfully tested and drive may be disconnected to proceed with next setup step.
 
Now if everything has gone well, you should see information like drive model and serial number on the Connect tab. Connection has been successfully tested and drive may be disconnected to proceed with next setup step.
 
 
==Disconnecting==
 
==Disconnecting==
To disconnect, just click '''Disconnect from drive''' button. Before disconnecting ensure following:
+
To disconnect, just click '''Disconnect''' button. Before disconnecting ensure following:
 
*Have you changed some parameters without pressing '''Apply settings''' button afterwards?
 
*Have you changed some parameters without pressing '''Apply settings''' button afterwards?
 
*Have you modified settings and wish to keep the changes? If yes, see [[#Loading and saving settings]]
 
*Have you modified settings and wish to keep the changes? If yes, see [[#Loading and saving settings]]
 
 
==Enable or disable motor control==
 
==Enable or disable motor control==
 
Enable/disable feature sets drive in active (enabled) or inactive (disabled) state. In enabled state drive performs motor control (such as positioning) and in disabled states drive lets motor free-wheel (torque off) or brakes motor.
 
Enable/disable feature sets drive in active (enabled) or inactive (disabled) state. In enabled state drive performs motor control (such as positioning) and in disabled states drive lets motor free-wheel (torque off) or brakes motor.
Line 55: Line 38:
 
*To disable drive, click '''Disable drive''' button or Esc key from anywhere in the software
 
*To disable drive, click '''Disable drive''' button or Esc key from anywhere in the software
 
*Alternatively set logic 0 to Enable drive physical input
 
*Alternatively set logic 0 to Enable drive physical input
{{Machine|Disabling drive by software is not reliable enough for emergenecy stopping. Always have hard-wired method available for emergency situations ([[safe torque off]] switch or cut all power)}}
+
{{Warning|Disabling drive by software is not reliable enough for emergenecy stopping. Always have hard-wired method available for emergency situations (safe toreque off switch or cut all power)}}
  
 
===Enabling drive===
 
===Enabling drive===
 
*To enable drive, click '''Enable drive''' buttton
 
*To enable drive, click '''Enable drive''' buttton
 
*In order to enable drive, logic 1 must be at drive physical Enable drive input
 
*In order to enable drive, logic 1 must be at drive physical Enable drive input
{{Machine|Before clicking enable, ensure that no danger is caused by unexpected motor behavior (such as servo instability or runaway).}}
+
{{Warning|Before clicking enable, ensure that no danger is caused by unexpected motor behavior (such as servo instability or runaway).}}
  
 
===Verifying current enable/disable status===
 
===Verifying current enable/disable status===
Line 66: Line 49:
  
 
==Loading and saving settings==
 
==Loading and saving settings==
[[File:Drive settings transfer princible.png|400px|thumb|Different locations and transfer ways of parameters between drive, Granity and file system]]
 
 
Drive parameters have three possible storage medias:
 
Drive parameters have three possible storage medias:
 
;Drive internal parameter memory (RAM)  
 
;Drive internal parameter memory (RAM)  
Line 76: Line 58:
 
*These parameters are automatically loaded to RAM during drive power-on
 
*These parameters are automatically loaded to RAM during drive power-on
 
*To store parameters from RAM to Flash, click '''Save settings to drive non-volatile memory''' button
 
*To store parameters from RAM to Flash, click '''Save settings to drive non-volatile memory''' button
;User interface (UI)
 
*Parameters visible on Granity user interface
 
*Can be modified by user
 
*UI parameters can be transferred to drive (Apply) or to file
 
 
;File on computer filesystem
 
;File on computer filesystem
 
*Parameters may be also stored and loaded from a file (file name ending: .drc)
 
*Parameters may be also stored and loaded from a file (file name ending: .drc)
Line 90: Line 68:
 
Some faults are clearable only by restarting drive. Restarting may be done by clicking '''Restart drive''' or by cycling 24VDC power. Restart is needed if Permanent stop status register bit is on. Note: Permanent stop bit is turned on also by changing certain parameters (not a fault).
 
Some faults are clearable only by restarting drive. Restarting may be done by clicking '''Restart drive''' or by cycling 24VDC power. Restart is needed if Permanent stop status register bit is on. Note: Permanent stop bit is turned on also by changing certain parameters (not a fault).
  
{{Machine|If drive is in enabled state during clear faults command, drive will become enabled automatically. Ensure safety before resetting faults.}}
+
{{Warning|If drive is in enabled state during clear faults command, drive will become enabled automatically. Ensure safety before resetting faults.}}
  
 
==Upgrading drive firmware==
 
==Upgrading drive firmware==
See the main article [[Granity user guide/Uploading a firmware]].
+
Preparations:
 +
#Ensure that communicatation works flawlessly to the device (in normal Granity operations)
 +
#Ensure that you have the firmware files
 +
##Original firmware (available from product site) - this file may be useful to restore device in factory state
 +
##A compatible new friwmare file for your device model & version
 +
Procedure to upgrade firmware on the device:
 +
#[[Setting device bus address|Set device address]] to firmware upgrade state and power up drive
 +
#Click '''Connect to drive'''
 +
#List of available devices pops up, open the one with firmware upgrade mode active
 +
#Firmware upgrade dialog pops up. Click '''Open file & start upgrade''' button
 +
#Firmware upgrade starts, wait until it finishes
 +
#Close upgrade dialog, power off the drive and restore the [[Setting device bus address|address]] settings to normal
  
 
==Troubleshooting==
 
==Troubleshooting==
* Check if LEDs are indicating an error (LEDs of: [[Argon user guide/LED indicators|Argon]], [[IONI & IONICUBE user guide/LED indicators|Ioni]])
+
* Check if [[Argon LED status indicators]] are indicating an error
* Ensure that each device in the bus has unique selected ([[Setting device bus address|Argon]])
+
* Ensure that each device in the bus has unique [[Setting device bus address|address]] selected
* Ensure correct interface device has been selected from the dropdown list. If multiple choices are shown, try the other ones. If adapter is not shown, try restarting Granity.
+
* Ensure correct interface device has been selected
* Ensure that bus termination has been properly set on only on the last drive in the bus  
+
* Ensure that [[Setting device bus address|bus termination]] setting has been properly set on only on the last drive in the bus
**[[Setting device bus address|Argon bus termination]]
+
**For IONICUBE (4 axis) ensure that jumper in JP10 position 3 is inserted
+
**For IONICUBE 1X, ensure that S1 position 1 is switched on)
+
*See [[Device connection troubleshooting]]
+
{{next|[[Granity user guide/Goals]]}}
+
 
+
[[Category:Granity_user_guide]]
+

Please note that all contributions to Granite Devices Knowledge Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Granite Devices Knowledge Wiki:Copyrights for details). Do not submit copyrighted work without permission!

Select categories:

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)