Testing tab

From Granite Devices Knowledge Wiki
< Granity user guide
Revision as of 17:23, 17 August 2013 by Tero K (Talk | contribs) (Capture controls)


Jump to: navigation, search

This tab serves following purposes:

  • Running repeating test sequence on motor
  • Capturing reference signal & feedback graphs from drive

Test stimulus generator

Test stimulus as numeric parameters and it's graphical representation

Test stimulus generator is a way to feed a repeating setpoint signal to the drive without having any other physical signals supplied. Test stimulus generates a square waveform with user specified amplitudes and timing.

The waveform generated is specified by 4 parameters:

Short GUI name GUI name Description How to use
TSP1 Target setpoint 1 The first setpoint level Adjust the value and observe the right side value conversion to the real world units such as amperes or millimeters.
TSD1 Delay 1 The active duration of the first setpoint Set the duration of the first setpoint lenght.
TSP2 Target setpoint 2 The second setpoint level Adjust the value and observe the right side value conversion to the real world units such as amperes or millimeters.
TSD2 Delay 2 The active duration of the second setpoint Set the duration of the second setpoint length.
TSE Enable test stimulues Control test stimulus feed Tick this checkbox to instantly start feeding test stimulus to the drive. Before ticking ensure that setpoints are set to safe levels and always be prepared stop motor safely if unexpected motion happens.
Example where
TSD1=0.1s
TSD2=0.5s
TSP1=1000→0.18A
TSP2=-500→-0.09A
Stimulusgraph m.png

Capture & graphs

Capture controls

Capture signals selection

Device state

Troubleshooting


In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.