Editing IONI connector pinout
Your changes will be displayed to readers once an authorized user accepts them. (help) |
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 180: | Line 180: | ||
| MECH_BRAKE_OUT ||Mechanical holding brake control output ||Use to control optional holding brake of motor ||A buffer circuit is needed to drive a solenoid brake, such as a logic level MOSFET. See example schematic [[Media:Regen drive.png|here]]. | | MECH_BRAKE_OUT ||Mechanical holding brake control output ||Use to control optional holding brake of motor ||A buffer circuit is needed to drive a solenoid brake, such as a logic level MOSFET. See example schematic [[Media:Regen drive.png|here]]. | ||
|- | |- | ||
− | |ENABLE_IN||Drive enable input signal (always required) ||Use to enable drive and allow motor to initialize and operate||Accepts up to 24V voltage level, but works also with | + | |ENABLE_IN||Drive enable input signal (always required) ||Use to enable drive and allow motor to initialize and operate||Accepts up to 24V voltage level, but works also with 3V level signal |
|- | |- | ||
− | |STO2||[[Safe torque off]] input signal (always required)||Use to allow motor to produce torque (activate power stage) ||Accepts up to 24V voltage level, but works also with 5V level signal. STO is inactive (allows torque) when logic high is supplied. | + | |STO2||[[Safe torque off]] input signal (always required)||Use to allow motor to produce torque (activate power stage) ||Accepts up to 24V voltage level, but works also with 5V level signal. STO is inactive (allows torque) when logic high is supplied. |
|} | |} | ||
− | |||
− | |||
==Electrical ratings== | ==Electrical ratings== | ||
[[File:Ioni io interlal circuits doc.png|thumbnail|right|IONI's internal circuity (equivalent schematics, not actual wiring) in feedback device port pins (the pins on D-15 connector on [[IONICUBE]]s)]] | [[File:Ioni io interlal circuits doc.png|thumbnail|right|IONI's internal circuity (equivalent schematics, not actual wiring) in feedback device port pins (the pins on D-15 connector on [[IONICUBE]]s)]] | ||
Line 217: | Line 215: | ||
| REGEN_OUT||Logic low 0V, logic high 3.3V||220||- | | REGEN_OUT||Logic low 0V, logic high 3.3V||220||- | ||
|- | |- | ||
− | | ENABLE_IN||Logic low -0.3- | + | | ENABLE_IN||Logic low -0.3-1.0V, logic high 2.7-26V||5k||10k pull-down to GND |
|- | |- | ||
| STO2||Logic low -0.3-2.0V, logic high 4.5-26V||8k||20k pull-down to GND | | STO2||Logic low -0.3-2.0V, logic high 4.5-26V||8k||20k pull-down to GND | ||
Line 266: | Line 264: | ||
#Adjust SMO parameter value so that device will receive a desired bus address. I.e. if using IONICUBE 1X, set SMO values 0, 1, 2, 3 to the different drives (drive addresses will become 1, 2, 3, 4). Or when IONICUBE (4 axis) is being used, set SMO values of drives on the first board 0, second board 4, third 8 etc (drive addresses will become 1 - 12). | #Adjust SMO parameter value so that device will receive a desired bus address. I.e. if using IONICUBE 1X, set SMO values 0, 1, 2, 3 to the different drives (drive addresses will become 1, 2, 3, 4). Or when IONICUBE (4 axis) is being used, set SMO values of drives on the first board 0, second board 4, third 8 etc (drive addresses will become 1 - 12). | ||
#Save settings, disconnect and repeat the procedure for all drives. | #Save settings, disconnect and repeat the procedure for all drives. | ||
− | |||
− | |||
− |