This page supports semantic in-text annotations (e.g. "[[Is specified as::World Heritage Site]]") to build structured and queryable content provided by Semantic MediaWiki. For a comprehensive description on how to use annotations or the #ask parser function, please have a look at the getting started, in-text annotation, or inline queries help page.

Latest revision Your text
Line 3: Line 3:
 
Please note, that these settings files are just templates that include the very basic motor settings. At least the following need to be adjusted according to the user's configuration to use these files successfully:
 
Please note, that these settings files are just templates that include the very basic motor settings. At least the following need to be adjusted according to the user's configuration to use these files successfully:
 
# FOV Over Voltage Fault Threshold has to be set to minimum of 102% of the supply voltage, i.e. for 48.0 V power supply, 49.5 V is recommended to have some margin.
 
# FOV Over Voltage Fault Threshold has to be set to minimum of 102% of the supply voltage, i.e. for 48.0 V power supply, 49.5 V is recommended to have some margin.
# FOC Over Current Tolerance has to be increased to Very High or Maximum. The motors typically will not initialize with the latest IONI servo drive firmwares using these configuration files.
+
# FOC Over Current Tolerance has to be increased to High or Maximum. The motors typically will not initialize with the latest IONI servo drive firmwares using these configuration files.
 
# Feedback device (encoder) settings have to be adjusted to match the feedback device in use.
 
# Feedback device (encoder) settings have to be adjusted to match the feedback device in use.
 
# FEV Over Speed Fault Threshold has to be adjusted so that the motor does not generate a fault condition if user turns the wheel too fast. In Granity, a threshold value of minimum of 6 rotations per second as indicated next to FEV field can be used as a guideline.
 
# FEV Over Speed Fault Threshold has to be adjusted so that the motor does not generate a fault condition if user turns the wheel too fast. In Granity, a threshold value of minimum of 6 rotations per second as indicated next to FEV field can be used as a guideline.
Line 107: Line 107:
  
 
If the calculated maximum torque is less than the motor peak torque, then it is not possible to achieve the specifies motor peak torque.
 
If the calculated maximum torque is less than the motor peak torque, then it is not possible to achieve the specifies motor peak torque.
 
[[Category:SimuCUBE]]
 
[[Category:SimuCUBE_user_guide]]
 
[[Category:Lists]]
 

Please note that all contributions to Granite Devices Knowledge Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Granite Devices Knowledge Wiki:Copyrights for details). Do not submit copyrighted work without permission!

Select categories:

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)