− | + | Granity from version 1.6.0 has a motor resistance and inductance measurement function that works with [[IONI]] drives. | |
− | + | ||
− | + | ||
==Checklist== | ==Checklist== | ||
Line 25: | Line 23: | ||
* Error recovering | * Error recovering | ||
* Homing | * Homing | ||
− | |||
− | |||
==Execution== | ==Execution== | ||
− | To start measurement, click "Measure resistance & inductance" button. The procedure takes about 10 seconds to complete and if sucessfull, the | + | To start measurement, click "Measure resistance & inductance" button. The procedure takes about 10 seconds to complete and if sucessfull, the [[MR]] and [[ML]] parameters will be updated by the measured values. |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + |