Granity 1.6.0 has a motor resistance and inductance measurement function that works with IONI drives.

To successfully measure, following conditions must be met:

  • Motor type selected
  • Motor connected and parameterized (except MR and ML can be any value)
  • Power on and enabled (any control mode)
  • If Brush DC motor, motor shaft must be mechanically locked in place

Device status must have all of following bits on:

  • Initialized
  • Enabled
  • Run
  • Voltages good

Device status must NOT have any of the following bits on:

  • Fault stopped
  • STO active
  • Permanent stop
  • Error recovering
  • Homing