Editing Servo motor torque mode test
Your changes will be displayed to readers once an authorized user accepts them. (help) |
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 21: | Line 21: | ||
#*If drive stops into overvelocity fault, it typically means that system works properly. However, you may increase {{param|FVT}} enough to complete the test without overvelocity fault. | #*If drive stops into overvelocity fault, it typically means that system works properly. However, you may increase {{param|FVT}} enough to complete the test without overvelocity fault. | ||
# If the motor moves in a continuous manner, all parameters and wiring are correct. | # If the motor moves in a continuous manner, all parameters and wiring are correct. | ||
− | #* If the motor halts, click the | + | #* If the motor halts, click the Set zero setpoint and follow the troubleshooting instructions below. |
== Troubleshooting == | == Troubleshooting == | ||
Line 27: | Line 27: | ||
* Check wiring, especially logic and motor voltages, Enable, and STO. | * Check wiring, especially logic and motor voltages, Enable, and STO. | ||
− | * Check | + | * Check FBI Invert feedback direction checkbox in Granity/Machine tab, and repeat the steps above. |
** This inverts the encoder direction without the need for rewiring. | ** This inverts the encoder direction without the need for rewiring. | ||
* Check the motor pole count and encoder resolution from their datasheets. | * Check the motor pole count and encoder resolution from their datasheets. | ||
Line 41: | Line 41: | ||
* For linear motors, please refer to [[Configuring linear servo motor|linear motor configuration instructions]]. | * For linear motors, please refer to [[Configuring linear servo motor|linear motor configuration instructions]]. | ||
* For stepping motors, please refer to [[Using stepping motor with IONI|stepping motor configuration instructions]]. | * For stepping motors, please refer to [[Using stepping motor with IONI|stepping motor configuration instructions]]. | ||
− | |||
− | |||
− | |||
− | |||
− |