#* Digital servo drives are practically sophisticated switching step-down voltage regulators, and the torque controller takes care that the current to the motor (and thus the voltage) is correct. | #* Digital servo drives are practically sophisticated switching step-down voltage regulators, and the torque controller takes care that the current to the motor (and thus the voltage) is correct. | ||
#* The HV can be at least five times the nominal motor voltage without any issues and reduced performance. | #* The HV can be at least five times the nominal motor voltage without any issues and reduced performance. | ||
− | # The maximum | + | # The maximum current to the motor is not the maximum current rating of the PSU |
#* Considered as a step-down regulator, the digital servo drive transfers power, not current to the motor. Because of this, the PSU's current rating affects maximum power that can be driven into a motor, not maximum current. | #* Considered as a step-down regulator, the digital servo drive transfers power, not current to the motor. Because of this, the PSU's current rating affects maximum power that can be driven into a motor, not maximum current. | ||
#* In ideal world, e.g. 48 V PSU with 10 A current rating can output 480 W power. If the required voltage to a motor to drive 24 A current is 20 V, the transferred power is the same what the PSU can supply. | #* In ideal world, e.g. 48 V PSU with 10 A current rating can output 480 W power. If the required voltage to a motor to drive 24 A current is 20 V, the transferred power is the same what the PSU can supply. | ||
Line 23: | Line 23: | ||
#* Before velocity or position tuning, the system must be tested without any load in torque mode to ensure proper functionality. | #* Before velocity or position tuning, the system must be tested without any load in torque mode to ensure proper functionality. | ||
#* Follow the instructions here: [[Servo motor torque mode test]]. | #* Follow the instructions here: [[Servo motor torque mode test]]. | ||
− | |||
− | |||
− | |||
− | |||
− |