Essential Basics

From Granite Devices Knowledge Wiki
Jump to: navigation, search

These basics are the most fundamental steps to get a motor running in order for an application to work properly.

  1. Motor supply voltage (HV) can be higher than nominal motor voltage
    • Digital servo drives are practically sophisticated switching step-down voltage regulators, and the torque controller takes care that the current to the motor (and thus the voltage) is correct.
    • The HV can be at least five times the nominal motor voltage without any issues and reduced performance.
  2. The maximum output current of the PSU is not the maximum current to the motor
    • Considered as a step-down regulator, the digital servo drive transfers power, not current to the motor. Because of this, the PSU's current rating affects maximum power that can be driven into a motor, not maximum current.
    • In ideal world, e.g. 48 V PSU with 10 A current rating can output 480 W power. If the required voltage to a motor to drive 24 A current is 20 V, the transferred power is the same what the PSU can supply.
  3. Encoder must be attached directly to the motor shaft
    • In practice, all gears and other such mechanics have non-idelities such as play, torsion, and/or possibility of slipping.
    • Play and torsion will introduce delay to the feedback loop, and will cause oscillation due to which the tuning is impossible to get precise.
    • Slipping encoder will give false data, which will cause the motor to either stall or run loose.
    • Encoder resolution must be exact for each rotation. Rounded data will also cause the known magnetic angle to be lost, and the motor will stall or run loose after few turns.
  4. Phasing a.k.a. phase search
    • If hall sensors or absolute encoder are not used, the motor needs to be rotated/moved to find a known magnetic angle. Only after this the encoder can give reliable information of the motor position so that it can be controlled properly.
    • If phasing is not done correctly in free motion, the motor can not be controller properly.
  5. STO (Safe Torque Off) and Enable
    • If SimpleMotion is not used, STO and Enable must be wired physically
    • In Granity 1.14.0 and later, both can be ignored for tuning.
  6. Torque tuning must be done properly
    • Poor torque tuning will result in excessive current spikes and at worst mechanical oscillation.
  7. Testing motor and encoder wiring in torque mode
    • Before velocity or position tuning, the system must be tested without any load in torque mode to ensure proper functionality.
    • Follow the instructions here: Servo motor torque mode test.
  8. SimpleMotion must be terminated properly only at the physical end of the bus

In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.