− | + | All [[SimpleMotion V2]] compatible devices have a settable address that identifies the device on a multidrop communication bus. Each device on the sharint the same bus must have an unique address number to make error free communication possible. For example configuring bus address is required to establish a connection with [[Granity]] software. | |
− | + | ||
− | + | ||
+ | If two or more devices are incorrectly set to have same address, packet collisions will happen in the bus causing communication failures. | ||
+ | ==Setting bus address various devices== | ||
+ | The method of how address is set depends on device hardware implementation. This chapter lists methods for Granite Devices products. | ||
===Argon=== | ===Argon=== | ||
[[File:Dipswitch.png|thumb|DIP switch of Argon. In this case the DIP has value 01001.]] | [[File:Dipswitch.png|thumb|DIP switch of Argon. In this case the DIP has value 01001.]] | ||
− | [[Argon (servo drive)]] has a 5 channel DIP switch that sets the address. The table below lists all possible settings of DIP switch settings | + | [[Argon (servo drive)]] has a 5 channel DIP switch that sets the address. The table below lists all possible settings of DIP switch settings. |
{| class="wikitable" | {| class="wikitable" | ||
Line 76: | Line 77: | ||
|- | |- | ||
|} | |} | ||
− | = | + | ===Bus termination=== |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | ==Bus termination== | + | |
[[File:Multidrop addressing.png|thumb|550px|Proper configuration of devices on a bus]]SimpleMotion V2 bus must be terminated for reliable communication. This means that last device of the bus must have termination DIP switch set to On position. | [[File:Multidrop addressing.png|thumb|550px|Proper configuration of devices on a bus]]SimpleMotion V2 bus must be terminated for reliable communication. This means that last device of the bus must have termination DIP switch set to On position. | ||
Bus may be also ''alternatively'' terminated with external 100 ohm resistor connected between RS485_A and RS485_B wires at the end of bus cable chain (see [[SimpleMotion V2 port]]). If DIP switch termination is used, then drive internal 100 ohm resistor is connected across the A and B wires. | Bus may be also ''alternatively'' terminated with external 100 ohm resistor connected between RS485_A and RS485_B wires at the end of bus cable chain (see [[SimpleMotion V2 port]]). If DIP switch termination is used, then drive internal 100 ohm resistor is connected across the A and B wires. | ||
− | === | + | ===Bus stub=== |
− | If an E-stop button is connected with RJ45 cable after the last device, a bus '''stub''' is formed. Stub must not be longer than 30 cm or 1 foot to ensure | + | If an E-stop button is connected with RJ45 cable after the last device, a bus '''stub''' is formed. Stub must not be longer than 30 cm or 1 foot to ensure bus operation. |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | Methods to elimiate the stub on E-stop cable: | |
− | + | *Cut the A and B wires (orange and orange/white) from the cable near connector and leave only the E-stob button wires left (green/white and blue/white) | |
− | + | *Alternatively, connect termination resistor at end of A and B pair and leave DIP switch termination off. |