Difference between revisions of "Measure motor resistance and inductance in Granity"
[checked revision] | [checked revision] |
(8 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | [[File:inductance.png|The definition of inductance|thumb]][[Granity]] setup software has a motor resistance and inductance measurement function that works with [[IONI]] drives. | |
+ | |||
+ | Using automatic measure is the new recommended approach to set {{param|MR}} and {{param|ML}} parameters accurately even when motor data sheet would provide these values. This is because many data sheets unfortunately provide inaccurate values. Some manufacturers have apparently characterized motor inductance at high frequency range (hundreds of kHz) which typically gives a value more than 50% off from the real inductance in typical laminated iron motors. | ||
==Checklist== | ==Checklist== | ||
Line 23: | Line 25: | ||
* Error recovering | * Error recovering | ||
* Homing | * Homing | ||
+ | |||
+ | {{tip|If these states change in the middle of the measurement, the outcome will be an error. In such case try analyze what is the cause of the error from the device status & fault bits.}} | ||
==Execution== | ==Execution== | ||
− | To start measurement, click "Measure resistance & inductance" button. The procedure takes about 10 seconds to complete and if sucessfull, the | + | To start measurement, click "Measure resistance & inductance" button. The procedure takes about 10 seconds to complete and if sucessfull, the {{param|MR}} and {{param|ML}} parameters will be updated by the measured values. |
+ | |||
+ | [[File:measureRL.png]] | ||
+ | |||
+ | ==Troubleshooting== | ||
+ | If the function fails and Under voltage fault is set, it typically means that HV DC power supply has been overloaded and caused drop of voltage. In such case, try setting motor current limits (MMC and MCC parameters) to a lower value and click Apply before executing the measure function. | ||
− | [[ | + | [[Category:IONI_features]] |
+ | [[Category:Granity_user_guide]] |
Latest revision as of 21:55, 1 March 2016
Granity setup software has a motor resistance and inductance measurement function that works with IONI drives.Using automatic measure is the new recommended approach to set Coil resistanceMR and Coil inductanceML parameters accurately even when motor data sheet would provide these values. This is because many data sheets unfortunately provide inaccurate values. Some manufacturers have apparently characterized motor inductance at high frequency range (hundreds of kHz) which typically gives a value more than 50% off from the real inductance in typical laminated iron motors.
Checklist[edit | edit source]
To successfully measure, following conditions must be met:
- Motor type selected
- Motor connected and parameterized (except MR and ML can be any value)
- Power on and enabled (any control mode)
- If Brush DC motor, motor shaft must be mechanically locked in place
Device status must have all of following bits on:
- Initialized
- Enabled
- Run
- Voltages good
Device status must NOT have any of the following bits on:
- Fault stopped
- STO active
- Permanent stop
- Error recovering
- Homing
If these states change in the middle of the measurement, the outcome will be an error. In such case try analyze what is the cause of the error from the device status & fault bits. |
Execution[edit | edit source]
To start measurement, click "Measure resistance & inductance" button. The procedure takes about 10 seconds to complete and if sucessfull, the Coil resistanceMR and Coil inductanceML parameters will be updated by the measured values.
Troubleshooting[edit | edit source]
If the function fails and Under voltage fault is set, it typically means that HV DC power supply has been overloaded and caused drop of voltage. In such case, try setting motor current limits (MMC and MCC parameters) to a lower value and click Apply before executing the measure function.