Line 24: | Line 24: | ||
New features: | New features: | ||
*Analog in setpoint now has direction input to support 0-10V sources with direction signal (in addition to standard +/-10V) | *Analog in setpoint now has direction input to support 0-10V sources with direction signal (in addition to standard +/-10V) | ||
− | *New AC/BLDC motor [[Phasing a.k.a. phase search|phasing algorithm]] | + | *New AC/BLDC motor [[Phasing a.k.a. phase search|phasing algorithm]]: |
**Improved operation when axis is heavy to move | **Improved operation when axis is heavy to move | ||
**Phasing now supports limit switches. Now it's possible to use Hall-sensorless phasing when axis lies at the end of travel or if axis is vertical and pulled down by gravity. Requires limit switches on axis and configuring [[LFS]] to other than ''Do nothing''. | **Phasing now supports limit switches. Now it's possible to use Hall-sensorless phasing when axis lies at the end of travel or if axis is vertical and pulled down by gravity. Requires limit switches on axis and configuring [[LFS]] to other than ''Do nothing''. |
Revision as of 00:03, 19 September 2013
This page lists the official firmware releases of the Argon (servo drive) and the change log.
- Glossary
- Firmware package - a firmware file with .gdf name extension that contains combined firmware for Argon I/O side processor and GraniteCore processor
- I/O side - the I/O side processor of Argon. The source code of this processor is open source.
- GraniteCore - the motion control processor inside the Argon.
- Change log - the list of changes made since the previous package version.
- Remarks - Notes
Firmware package version | Date | I/O side version | GraniteCore version | Change log | Remarks | Importance |
---|---|---|---|---|---|---|
0.9.0 | 1.7.2013 | 1000 | 1000 | Development version | Shipped with the first production batch | |
1.0.0 download | 1.9.2013 | 1000 | 1005 | Initial official release | A requirement for Granity 1.0.0 | |
1.0.1 download | 3.9.2013 | 1000 | 1006 |
|
A requirement for Granity 1.0.1 | Functional |
1.0.2 download | 18.9.2013 | 1001 | 1007 |
New features:
Bug fixes:
Adjustments:
|
A requirement for Granity 1.0.2 Re-tuning may be necessary after upgrade! |