Difference between revisions of "Tracking error"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
m (Text replacement - "\[\[([A-Z]{2,3})\]\]" to "{{/param\|\1/}}")
Line 2: Line 2:
  
 
==Tracking error fault==
 
==Tracking error fault==
In modern motor drives it's possible to define the permissible maximum value of tracking error which is allowed before drive enters in a fault state and stops. Tracking fault is useful for protecting the machine or users from damage if something is preventing mechanism from moving. In [[Granity]] this value is entered in [[FPT]] and [[FVT]] parameters.
+
In modern motor drives it's possible to define the permissible maximum value of tracking error which is allowed before drive enters in a fault state and stops. Tracking fault is useful for protecting the machine or users from damage if something is preventing mechanism from moving. In [[Granity]] this value is entered in {{/param\|FPT/}} and {{/param\|FVT/}} parameters.
  
 
===Fault countermeasures===
 
===Fault countermeasures===
 
Tracking error fault is probably the most common fault in servo motor systems. Typical reasons and counter measures are:
 
Tracking error fault is probably the most common fault in servo motor systems. Typical reasons and counter measures are:
 
*Wrong motor settings:
 
*Wrong motor settings:
**If motor jumps without command after start-up, the issue probably is wrong feedback counting direction → try changing [[FBI]] setting.
+
**If motor jumps without command after start-up, the issue probably is wrong feedback counting direction → try changing {{/param\|FBI/}} setting.
**If motor type is AC/BLDC, then feedback resolution [[FBI]] and pole count [[MPC]] must be correctly entered. If not, then symptoms are that motion is limited to narrow range to both directions from starting location and going beyond certain point causes tracking error fault → Check [[MPC]] and [[FBR]]. If unsure, contact [[Granite Devices support|support]] with attached feedback device and motor data sheet.
+
**If motor type is AC/BLDC, then feedback resolution {{/param\|FBI/}} and pole count {{/param\|MPC/}} must be correctly entered. If not, then symptoms are that motion is limited to narrow range to both directions from starting location and going beyond certain point causes tracking error fault → Check {{/param\|MPC/}} and {{/param\|FBR/}}. If unsure, contact [[Granite Devices support|support]] with attached feedback device and motor data sheet.
*Too low fault tolerance levels → Increase [[FPT]], [[FVT]] and/or [[FFT]] parameters
+
*Too low fault tolerance levels → Increase {{/param\|FPT/}}, {{/param\|FVT/}} and/or {{/param\|FFT/}} parameters
 
*Bad servo tuning → Adjust feedback gains, see [[Servo motor tuning guide]]
 
*Bad servo tuning → Adjust feedback gains, see [[Servo motor tuning guide]]
 
*Asking too much out of motor so motor can't keep up with motion:
 
*Asking too much out of motor so motor can't keep up with motion:
**Too fast acceleration → reduce acceleration rate [[CAL]] OR increase motor current limits, especially [[MMC]]
+
**Too fast acceleration → reduce acceleration rate {{/param\|CAL/}} OR increase motor current limits, especially {{/param\|MMC/}}
**Too fast velocity → reduce velocity limit [[CVL]]. If motor can't reach it's full speed, reason may be too low drive supply voltage or partial loss of encoder signal (encoder not being able to operate at such speeds or interference/bad wiring is causing the error)
+
**Too fast velocity → reduce velocity limit {{/param\|CVL/}}. If motor can't reach it's full speed, reason may be too low drive supply voltage or partial loss of encoder signal (encoder not being able to operate at such speeds or interference/bad wiring is causing the error)
  
  

Revision as of 19:59, 28 August 2015

Tracking error means the difference between the setpoint and measured actual output value. For example in a linear axis tracking error can be the distance between setpoint position and the position where axis really lies at the given moment.

Tracking error fault

In modern motor drives it's possible to define the permissible maximum value of tracking error which is allowed before drive enters in a fault state and stops. Tracking fault is useful for protecting the machine or users from damage if something is preventing mechanism from moving. In Granity this value is entered in Tracking error/param\ and Tracking error/param\ parameters.

Fault countermeasures

Tracking error fault is probably the most common fault in servo motor systems. Typical reasons and counter measures are: