Difference between revisions of "Simucube 2 documentation"
[checked revision] | [checked revision] |
(→Service manuals) |
(→Service manuals) |
||
Line 15: | Line 15: | ||
Cause: Internal cable for the power button is placed in a bad location inside the device. | Cause: Internal cable for the power button is placed in a bad location inside the device. | ||
Note: This service instruction is only applicable to Simucube 2 Sport and Pro R1 units (Pro with 2 power supplies) that were produced before August 2020. | Note: This service instruction is only applicable to Simucube 2 Sport and Pro R1 units (Pro with 2 power supplies) that were produced before August 2020. | ||
− | + | * {{dlfile|SC2_Sport_&_Pro_R1_power_button_wire_check.pdf|Simucube 2 Sport/Pro R1 power button wire check (PDF)}} | |
Problem: The external antenna connector is loose. | Problem: The external antenna connector is loose. |
Revision as of 15:49, 25 January 2021
This page lists all officially published documentation of Simucube 2 systems. The main Simucube 2 product website is at https:///www.simucu.be
Software
see Simucube 2 True Drive software releases
User manuals
Service manuals
Problem: Wheel is slipping and center point is changing. Cause: The conical shaft adapter is slipping. This affected many of the very first produced Simucube 2 units in May 2019.
Problem: Device stuck in "Waiting for drive to get ready" and does not start correctly. The E-stop button status follows the real e-stop button. Cause: Internal cable for the power button is placed in a bad location inside the device. Note: This service instruction is only applicable to Simucube 2 Sport and Pro R1 units (Pro with 2 power supplies) that were produced before August 2020.
Problem: The external antenna connector is loose. Cause: Loose antenna connector. Note: Do not spin the antenna connector to not cause it to wind up and break.