Difference between revisions of "Fault location"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(→List of Fault location ID 1) |
(→List of Fault location ID 1) |
||
Line 28: | Line 28: | ||
| 5501 || Unsupported motor type [[MT]] not selected || Choose [[MT]] | | 5501 || Unsupported motor type [[MT]] not selected || Choose [[MT]] | ||
|- | |- | ||
− | | 6601 || [[Phasing a.k.a. phase search]] failed || Check motor settings, wiring and supply voltage. Also happens if drive is disabled during initialization. | + | | 6601 || [[Phasing a.k.a. phase search]] failed || Check motor settings, wiring and supply voltage. Also happens if drive is disabled or hit limit switch during initialization. |
|- | |- | ||
| 6602 || [[Phasing a.k.a. phase search]] failed due to both limit switches being open || Check limit switch settings and switch operation | | 6602 || [[Phasing a.k.a. phase search]] failed due to both limit switches being open || Check limit switch settings and switch operation |
Revision as of 12:46, 12 February 2014
Fault location ID 1 & 2 that are displayed on Granity Testing tab Device state section. Fault locations are detailed numeric codes giving a hint what was the precise reason causing a fault state.
List of Fault location ID 1
Fault location ID 1 | Reason | Solution |
---|---|---|
1-2 | Current sensing range exceeded | See solutions of 120 and 600. |
100,110,200,220,2100-2126 | Loading or saving settings in drive memory failed | Programming error, contact developers |
120 | Short circuit protection triggered (very high & fast current rise detected) | Check wiring for shorts, ensure that motor inductance is sufficient (especially ironless & pancake motors), perform Tuning position controller, adjust FOC. |
600 | Overcurrent protection triggered (slower reaction but lower current level than short circuit protection) | Check wiring for shorts, ensure that motor inductance is sufficient (especially ironless & pancake motors), perform Tuning position controller, adjust FOC. |
2050 | Attempted to set fault bit active in clear faults function | Programming error, contact developers |
2320-2321,2330,2340 | Communication error between GraniteCore processors | Contact Granite Devices if problem repeats |
3001 | Hall sensors are enabled but no valid signals present (all hall inputs 0's or 1's which is illegal state) | Check wiring and settings |
3060 | Power stage fault signal active (possible overtemperature, logic circuit undervoltage, Safe torque off | Contact Granite Devices if problem repeats |
3070 | Power stage fault signal 2 active (possible overtemperature, logic circuit undervoltage, Safe torque off | Contact Granite Devices if problem repeats |
5500 | Motor type MT not selected | Choose MT |
5501 | Unsupported motor type MT not selected | Choose MT |
6601 | Phasing a.k.a. phase search failed | Check motor settings, wiring and supply voltage. Also happens if drive is disabled or hit limit switch during initialization. |
6602 | Phasing a.k.a. phase search failed due to both limit switches being open | Check limit switch settings and switch operation |
9996-9999 | Internal range check of internal variable failed | Programming error, contact developers |
List of Fault location ID 2
The list is incomplete. In case of other errors, contact Granite Devices support.
Fault location ID 2 | Reason | Solution |
---|---|---|
100202 | GraniteCore status update failed | Programming error, contact developers |
600101-600106 | GraniteCore connection failed | Programming error, contact developers |
480301 | Extracting payload from SMV2 packet failed | Check SMV2 communication |
480501 | SMV2 buffer overflow | SMV2 application error |
480502 | SMV2 command corrupted because it has overflown payload buffer size | SMV2 application error |
480503 | SMV2 return data buffer overflow | SMV2 application error |
480601 | Invalid SMV2 command | SMV2 application error |
480901 | SMV2 communication timeout | SMV2 application error |
480801 | Invalid SMV2 SMP packet type | SMV2 application error |
480901 | SMV2 packet CRC error | Communication error |
710301 | Command queue to GraniteCore full | Programming error, contact developers |
200101-200801 | I/O side CPU error interrupt triggered | Programming error or hardware issue (supply voltage? EMI?) |
100101 | Reading init state from GraniteCore failed | Programming error, contact developers |