Difference between revisions of "Measure motor resistance and inductance in Granity"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
m (Text replacement - "\[\[([A-Z]{2,3})\]\]" to "{{param|$1}}")
Line 1: Line 1:
 
[[File:inductance.png|The definition of inductance|thumb]][[Granity]] setup software has a motor resistance and inductance measurement function that works with [[IONI]] drives.
 
[[File:inductance.png|The definition of inductance|thumb]][[Granity]] setup software has a motor resistance and inductance measurement function that works with [[IONI]] drives.
  
Using automatic measure is the new recommended approach to set [[MR]] and [[ML]] parameters accurately even when motor data sheet would provide these values. This is because many data sheets unfortunately provide inaccurate values. Some manufacturers have apparently characterized motor inductance at high frequency range (hundreds of kHz) which typically gives a value more than 50% off from the real inductance in typical laminated iron motors.
+
Using automatic measure is the new recommended approach to set {{param|MR}} and {{param|ML}} parameters accurately even when motor data sheet would provide these values. This is because many data sheets unfortunately provide inaccurate values. Some manufacturers have apparently characterized motor inductance at high frequency range (hundreds of kHz) which typically gives a value more than 50% off from the real inductance in typical laminated iron motors.
  
 
==Checklist==
 
==Checklist==
Line 27: Line 27:
  
 
==Execution==
 
==Execution==
To start measurement, click "Measure resistance & inductance" button. The procedure takes about 10 seconds to complete and if sucessfull, the [[MR]] and [[ML]] parameters will be updated by the measured values.
+
To start measurement, click "Measure resistance & inductance" button. The procedure takes about 10 seconds to complete and if sucessfull, the {{param|MR}} and {{param|ML}} parameters will be updated by the measured values.
  
 
[[File:measureRL.png]]
 
[[File:measureRL.png]]
 
[[category:Granity user guide]]
 
[[category:Granity user guide]]
 
[[category:IONI features]]
 
[[category:IONI features]]

Revision as of 19:58, 28 August 2015

The definition of inductance
Granity setup software has a motor resistance and inductance measurement function that works with IONI drives.

Using automatic measure is the new recommended approach to set Coil resistanceMR and Coil inductanceML parameters accurately even when motor data sheet would provide these values. This is because many data sheets unfortunately provide inaccurate values. Some manufacturers have apparently characterized motor inductance at high frequency range (hundreds of kHz) which typically gives a value more than 50% off from the real inductance in typical laminated iron motors.

Checklist

To successfully measure, following conditions must be met:

  • Motor type selected
  • Motor connected and parameterized (except MR and ML can be any value)
  • Power on and enabled (any control mode)
  • If Brush DC motor, motor shaft must be mechanically locked in place

Device status must have all of following bits on:

  • Initialized
  • Enabled
  • Run
  • Voltages good

Device status must NOT have any of the following bits on:

  • Fault stopped
  • STO active
  • Permanent stop
  • Error recovering
  • Homing

Execution

To start measurement, click "Measure resistance & inductance" button. The procedure takes about 10 seconds to complete and if sucessfull, the Coil resistanceMR and Coil inductanceML parameters will be updated by the measured values.

MeasureRL.png