Difference between revisions of "Using stepping motor with IONI"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
m (Seting up closed loop mode 2)
(Setting up closed loop mode 2: fix)
Line 54: Line 54:
  
 
==Setting up closed loop mode 2==
 
==Setting up closed loop mode 2==
In this mode, follow parameterization of closed loop mode except:
+
In this mode, follow parameterization of open loop mode (mode 1) except:
 
;[[FBD]] Feedback device
 
;[[FBD]] Feedback device
 
:Choose your feedback device (other than None)
 
:Choose your feedback device (other than None)
Line 71: Line 71:
 
:2 Phase AC or BLDC
 
:2 Phase AC or BLDC
 
;[[MPC]] Pole count
 
;[[MPC]] Pole count
:100 [[Category:IONI_user_guide]] [[Category:Setup_guides]]
+
:100   [[Category:IONI_user_guide]] [[Category:Setup_guides]]

Revision as of 12:53, 19 May 2016

Using stepping motor with IONI drive is possible in three ways:

Mode1 - Open loop (no encoder)
This is the traditional stepping motor drive method. Will achieve highest speed and is easily configurable but there is no feedback, so if motor stalls/loses synchronism, the absolute position will be unknown before referencing/homing.
Mode 2 - Closed loop (with encoder feedback)
This is open loop mode combined with encoder feedback. The advantages are that drive can detect loss of synchronism and restore to commanded position with clear faults command. May be used also with linear encoder to enhance system accuracy.
Mode 3 - Servo (with encoder feedback)
In this mode, a stepping motor is used as high pole count brushless servo motor. In this mode, motor efficiency is high (no current if no load) and motor do not lose synchronism. However, motor speed is limited by back EMF of motor and typically can achieve lower top speed than the other modes. In this mode stepper can be also safely driven over it's rated current to get higher peak torque than it's rated torque (like a servo motor).

In the modes 1 and 2 stepper is driven with constant current drive and the motion produced by adjusting phase angle (traditional stepper drive method). In the mode 1 phase angle is controlled directly by setpoint trajectory and in mode 2 it is controlled by encoder based feedback loop. In the mode 3 motor current is controlled by torque controller (from zero to peak current limit) while phase angle is synchronized to rotor angle by the help of encoder. Mode 3 is similar to servo motor control (more details).

Setting up open loop mode 1

In this mode, drive emulates encoder internally and some tuning parameters need to be set to allow operation:

MT Motor type
Stepping motor
FBD Feedback device
None
FBI Invert feedback direction
Unticked
FBR Feedback device resolution
6400 (this is the emulated encoder resolution, 6400 PPR = 25600 steps/rev)
MCC Motor continuous current
This is the resting current when motor stands still. Drive will switch to this after 0.5 seconds of standing still.
MMC Motor peak current limit
This is the motor rated current that is used when motor is rotating.
MR Motor coil resistance
See motor datasheet or if not known, start with low values such as 1 ohm
ML Motor coil inductance
See motor datasheet or if not known, start with low values such as 1 mH
CM Control mode
Set to Position control (typical) or Velocity control mode
KVP Velocity P gain
0
KVI Velocity I gain
900
AFF and VFF
0
KPP Position P gain
150
PFF Position feed-forward gain
100%
FEV Over speed fault
1000
FPT and FVT fault limits
1000

Other settings are not critical and can be configured as desired (such as acceleration and velocity limits). If setpoint scaling is 1:1 (MUL=DIV), then this mode yields resolution of 25600 steps/revolution. If reduction of resolution is required, then adjust scaling accordingly (if scaling is set above 4:1, then try also Setpoint smoothing CIS).


NOTE: these values and settings apply from firmware version 1.2.1 (1064). For older firmware version, check out earlier version of this page here.

Setting up closed loop mode 2

In this mode, follow parameterization of open loop mode (mode 1) except:

FBD Feedback device
Choose your feedback device (other than None)
FBI Invert feedback direction
Try both settings and choose the one with stability
FBR Feedback device resolution
Set your feedback device resolution
KVI and KPP
Tune KVI and KPP values (and possibly other gains if non-zero) to have nice response
FMO Motion fault limit
Set non-zero value (perhaps 100-1000) to cause a fault state when motor stalls

Setting up servo mode 3

To set-up stepper as servo motor, just follow the IONI & IONICUBE user guide and consider the stepper motor as servo motor. For a typical 1.8 degree/step two-phase stepping motor the correct motor type parameters are:

MT Motor type
2 Phase AC or BLDC
MPC Pole count
100