If SimuCUBE is always stuck in DFU mode, then see the following instructions and notes below.
If the switch fails to make contact (resistance always higher than 1kOhm), then it is the likely reason for the problem. Try to operate switch several times to make possible corrosion to disappear.
Note: unused SimuCUBE from factory will contain a special firmware that will place the device in DFU mode regardless of DIP switch setting. So another reason for persistent DFU mode may be that uploading of main firmware has failed, and the factory default FW is still inside.