This is the intallation & user guide for the Intensify Nx50 laser diode driver. Read it through before operating the device.
Contents
Overview
Wiring
CMD connector
CMD connector is a 10 pin flat ribbon cable connector with 0.1"/2.54 mm pin pitch and a polarity key.
Header text | Header text | Header text |
---|---|---|
1 | PULSE | Pulse control. When low, output low current and when high, output setpoint current. |
2 | GNDA | Analog ground |
3 | IMON+ | Current monitor positive output (differential) |
4 | IMON- | Current monitor negative output (differential) |
5 | VMON+ | Voltage monitor positive output (differential) |
6 | VMON- | Voltage monitor negative output (differential) |
7 | ISET+ | Current setpoint positive input (differential) |
8 | ISET- | Current setpoint negateive input (differential) |
9 | ENABLE | Enable input. When low, output enabled and high or open, output disabled. |
10 | GND | Power & digital ground |