Intensify Nx50 |
---|
280px |
Device type |
Laser diode driver |
---|
Control modes |
Current control |
---|
Status |
Prototypes |
---|
Electrical |
---|
DC supply voltage |
11-13 VDC |
---|
Output current range |
0.1 - 50A × number of stacked boards |
---|
Setpoint signals |
Analog reference for current control, Digital signals for enable & pulsing |
---|
Feedback devices |
On-board current & voltage sensing |
---|
Protections |
Over temperature, under voltage, short circuit, laser diode protection |
---|
LD forward voltage |
0.8 .. 5.0 VDC |
---|
Ripple current (typ @ 50A) |
0.2A RMS, 1.25A pk-pk |
---|
General |
---|
Dimensions |
94×77.5×17 mm |
---|
Configuration tool |
No software tools needed |
---|
Web site |
Intensify product site
|
---|
Technical specifications
Power
Property |
Value |
Units |
Remarks
|
Supply voltage |
12 +/- 1 |
V |
|
Supply current |
0.1 - 24 |
A |
Depends on output power
|
Max output power |
250 |
W |
50A @ 5.0V
|
Output voltage |
0.8 - 5.0 |
V |
Determined by laser diode voltage drop
|
Output current |
0 - 50 |
A |
Continuous rating
|
Efficiency |
95 |
% |
Efficiency when Io > 20A and Vo > 5V
|
Intensify Nx 50 is a stackable constant current laser diode bar driver delivering up to 150A CW current. Parallel capability allows stacking multiple Intensify boards to scale up the power. Intensify is intended for OEM applications such as fiber laser pumping, laser tooling and laser diode burn-in.
Time properties
Property |
Value |
Units |
Remarks
|
Pulsed LD current rise time |
0.5 typ |
ms |
Current rise from 10% to 90% of setpoint
|
Pulsed LD current rise time |
0.6 typ |
ms |
Current fall from 10% to 90% of setpoint
|
Enable delay |
< 60 |
ms |
From disabled to enabled state
|
Disable delay |
< 2 |
ms |
From enabled to disabled state
|
Power-up/down sequence |
Any order. Any I/O line states not causing spiking above setpoint |
|
|
Inputs/outputs
Property |
Value |
Units |
Remarks
|
Current setpoint voltage |
0..10 |
V |
0..10 V sets LD current between 0..50 A
|
Current setpoint input impedance |
50k |
Ω |
Differential input
|
Current monitor output voltage |
0..10 |
V |
0..10 V represents LD current between 0..50 A
|
Current monitor output impedance |
200 |
Ω |
|
Voltage monitor output voltage |
0..5.5 |
V |
Represents LD voltage drop 1:1
|
Voltage monitor output impedance |
200 |
Ω |
|
Enable input voltage |
- -0.3..1 V or open circuit = disabled
- 2.5..13 V = enabled
|
V |
Enable is 3.3V, 5V and 12V logic compatible
|
Pulse input voltage |
- -0.3..1 V or open circuit = pulse high
- 2.5..13 V = pulse low
|
V |
Pulse is 3.3V, 5V and 12V logic compatible. Pulse high outputs current defined by setpoint, pulse low outputs current 0.035*setpoint.
|
Mechanical & environmental
Property |
Value |
Units |
Remarks
|
Dimensions |
94×77.5×17 |
mm |
W×H×D
|
Operating temperature range |
-40..85 |
°C |
Non condensing. Output rating may derate at high temperature without forced convection
|
Reliability MTBF |
1.5 |
106 Hrs |
Per Bellcore TR-332 50% stress, Tamb = 40 °C
|
ESD protection |
Exceeds ESD Protection to IEC61000-4-2 Level 4, ±12 kV discharge |
|
All I/O lines
|
Literature
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.