Configuring cogging torque compensation

From Granite Devices Knowledge Wiki
Revision as of 11:17, 28 May 2016 by Tero K (Talk | contribs)


Jump to: navigation, search
Cogging and anticogging explained.
Cogging torque compensation feature in drive that aims to make motor torque production more uniform and ideal.

"Cogging torque of electrical motors is the torque due to the interaction between the permanent magnets of the rotor and the stator slots of a Permanent Magnet (PM) machine. It is also known as detent or ‘no-current’ torque. This torque is position dependent and its periodicity per revolution depends on the number of magnetic poles and the number of teeth on the stator.”

This can be compensated by modulating motor current to counter the motor cogging. In some Granite Devices drives (IONI Pro family on the time of writing) there are options to adjust compensation current by few parameters.


Configuration

TorqueCompensation.png

Cogging torque compensation parameters in Granity

Parameters

Static no-current cogging compensation is done by summing a fixed amplitude waveform on the torque setpoint. The default waveforms are sinusoidal where phase angle of sine is driven by motor angle.

  • Cogging compensation functionTRF1 - selects the function of compensator
  • Cogging compensation currentTRA1 - adjusts the amplitude of summed torque command

Dynamic torque ripple compensation helps to reduce non-uniform torque when non-zero current is being driven. The method of operation is same, except this time setpoint amplitude is modulated by scaling of torque setpoint.

  • Torque ripple compensation functionTRF2 - selects the function of compensator
  • Torque ripple compensation amplitudeTRA2 - adjust the modulation depth of compensator

Finding values

The first task is to determine the frequency of imperfections so we know which functions to start experimenting.

Determining cogging torque frequency is straight forward.

  1. Rotate unpowered motor by hand count the number of major "steps" or "cogs" per revolution
  2. Divide this number by motor poles and multiply by two. So equation is N=2*number_of_cogs/pole_count (same as Pole countMPC.
  3. The optimal TRF1 function is either Sin(Nx) or Cos(Nx). For example, if motor has 8 poles, and we feel 12 cogs per revolution, the value of N becomes 2*12/8=3. So in this case we would use Sin(3x) or Cos(3x) function.

As the frequency is known, we proceed choosing the correct function and amplitude setting:

  1. Set drive in torque mode and enable it without any setpoint
  2. Start with Sin(Nx) function and try different TRA2 values (positive and negative, varying magnitudes). On each TRA2 value, try rotating motor by hand and identify the lowest cogging setting.
  3. Repeat the last step but this time with Cos(Nx) function.
  4. Choose the settings that yielded the lowest cogging

Perform the above procedure first for cogging torque, and then for ripple if necessary. However, in the ripple settings (TRF2 and TRA2), the test & comparison should be conducted when torque setpoint is set to a constant non-zero value (i.e. using Target setpoint 1TSP1 and Set Abs button. In this case, motor should be held still and rotated by hand to determine the lowest ripple settings.


In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.