SimuCUBE firmware user guide
The user guide for the SimuCUBE firmware can be found here: SimuCUBE Firmware User Guide
SimuCUBE firmware files
Stable SimuCUBE firmware is not yet published. Until then, please consider using MMos firmware for production purposes.
Please note that this version history table only lists collected changes after each publicly released version.
Date
|
Firmware / Configuration
Tool version
|
Included IONI firmware version
|
Closed / Open / Official |
FW file |
Description/changes/new features
|
February, 2018
|
0.9.4 / 0.9.4
|
10700
|
Public beta release
|
|
Upcoming release.
New features
- Branding support
- Those resellers that want their own logo to replace the Granite Devices SimuCUBE logo on the UI, please send a logo for approval and whitelisting. You should know who to contact by email or on our community forums.
- Suitable image size: 400px wide and 50px height PNG file with optional transparency.
- All users can replace the wheel image with their own image.
- Suitable image size: 400x400 px, PNG with transparency set.
- Configuration Tool will detect a SimuCUBE in Firmware Upgrade Mode and shows the firmware prompt automatically.
- Configuration Tool now has new, nice app icon.
- Configuration Tool will ask for user to accept End User License Agreement (new version of the license will replace the old.)
- Desktop Centering Spring has adjustable minimum force saturation to enable more strict centering of the wheel.
- Desktop Centering Spring has adjustable damper, to dampen the oscillations especially if too much saturation is used.
Bug fixes
- The Configuration Tool will not always prompt about unsaved settings on start, even if user did not change settings.
- Regaining communications to IONI drive after Granity mode is fixed.
- Automatic IONI drive firmware update seems to have been broken since at least 0.9.0 version. It has been fixed.
IONI Firmware update 1.7.0
|
January 26th, 2018
|
0.9.2 / 0.9.3
|
10601
|
Public beta release
|
[1]
|
Bug fix:
- Configuration tool will export simucubeprofiles.ini again, instead of corrupting VERSION file.
New features:
- Configuration tool will automatically backup profiles to profiles_autobackup.ini when user presses the Save settings to flash -button.
Note: Firmware has not been changed. Just unzip this new version and use it instead of previous versions.
|
January 25th, 2018
|
0.9.2 / 0.9.2
|
10601
|
Public beta release
|
[2]
Please take note to get 0.9.2.zip file.
|
Bug fixes:
- Infinite length effect, as set by some game titles such as RaceRoom, is now correctly parsed
New features:
- Configuration Tool will now always automatically show a prompt to update firmware if a newer firmware file is found than that found installed in SimuCUBE.
- Configuration Tool will now show a notification dialog and gracefully close, if a too new firmware is already installed in SimuCUBE.
|
January 25th, 2018
|
0.9.1 / 0.9.1
|
10601
|
Public beta release
|
[3]
|
New features:
- USB effect duration is being parsed correctly for the currently implemented effects that are generally meant to be changing automatically over time, so timed effects also end at the correct time.
- Please report if any games use timed spring, constant force, constant sine offset or any other timed effects.
- symptom is a feeling of "neverending effect stuck on".
- Desktop Centering spring has been implemented. It is off by default.
- Interaction of the centering spring force and the bumbstop effect force has not been optimized and might give funny results.
- When running the Motor Configuration Wizard, the centering spring is re-set to off. User must manually re-enable it.
Improvements:
- Configuration Tool is built with Qt 5.10 with improved high-DPI / custom scaling factor support.
Bug fixes:
- Firmware and Configuration Tool can manage to configure the system also to an empty SimuCUBE or when upgrading from MMOS
- UPGRADING FROM MMOS to this or later version: No extra steps required anymore.
- Torque peaking and notch filter will grey out the Attenuation and Center Q Factor values properly again in the UI
- Some IONI drive connection/reconnection issues have been fixed. Please report on our forums if there still appears to be any issues.
Known issues:
- Estimated torque calculation is wrong
Remember to actually update the firmware after unzipping via the Update Firmware -button.
|
January 16th, 2018
|
0.9.0 / 0.9.0
|
10601
|
Public beta release
|
[4]
|
Highlights: Event logging, Bumbstop damping improvement, FFB effects, FFB USB report parsing improvements and reordering of profiles.
UPGRADING FROM MMOS to 0.9.0:
Please use version 0.8.12 for any new firmware installs when coming from MMOS or a fresh SimuCUBE board. A bug has been found in the initial setup wizard on 0.9.0, which will be fixed very soon.
Important note about upgrading:
- Please activate a profile with 100% strength by using the previous Configuration Tool version before updating. This is to have the correct maximum MMC at the drive when new firmware boots up. This is only required for this version, and is fixed for future releases.
- If you forget to do this, power-cycling the SimuCUBE will also reset the setting to the correct one on IONI drive.
New features:
- SimuCUBE logs firmware state changes and other data into a log, which can be downloaded via "Download Event Log" button on the advanced tab in the Configuration tool.
- In the same tab, user can set logging to include state changes and other basic stuff OR ffb effect creation/start/stop events OR ffb effect calculation results. The latter two types are not yet logging anything, they are reserved as future debugging helpers.
- Following DirectInput effects have been implemented: Sine wave, Square Wave, Triangle Wave, SawtoothUp, SawtoothDown, Spring
- Sliders to set strength of each of these is available in the UI. Values for the new sliders are random for existing profiles - please adjust them.
- Each of the sliders has any effect only when a game is setting such an effect to use via DirectInput.
- You can check which effects games are using by looking at the advanced tab while driving.
- Profiles can be re-ordered via new dialog
Improvements:
- Bumbstop effect damping has been reworked and improved.
- Motor fault codes are read in initialization phase, instead of just checking for success/failure of initialization.
- It is not possible anymore to end up in Operational mode via complex state changes when initial motor settings are not configured at least once via the wizard.
- Added reading of HV Bus Voltage and FOV values if waited for initialization for more than 30s. FOV must be larger than HV Bus Voltage + 2% for the IONI to init. There is an error message explaining this now.
- Improved resiliency against misconfigured IONI drives, such as bus address offset being other than 0.
- Some handling of USB Suspend and RESET commands. It is unlikely that this would solve Computer Hangs Boot -issue.
Bug Fixes:
- Improved timeliness for USB FFB effect command parsing. This bug caused some FFB effects to not always get initialized for some game titles.
- 100% IONI MMC is set to the drive right before going to Firmware Upgrade Mode, so that after the update the correct 100% MMC can be read from the drive.
Known issues:
- Estimated torque calculation is wrong
- Rarely, re-enabling SimpleMotion communications from the USB Configuration Mode fails, and firmware will go into reconnect loop. Re-enabling IONI USB communications and switching back can be used to connect drive.
Bootloader:
- Bootloader has been updated to v1.2.1.
- Initialize the TXEN pin on the SimpleMotion bus as input, so user can connect to IONI drive via Granity after putting SimuCUBE firmware into bootloader mode.
- USB control reply sending fix that was also done for SimuCUBE Firmware release 0.8.3. It is unlikely that this bug could affect bootloader, but the fix is copied to bootloader anyway.
- There is a slight delay before booting out of bootloader mode by command from PC. This is to allow enough time for the Configuration Tool on PC to properly disconnect from bootloader.
- Bootloader remains 100% compatible otherwise.
- Users do not need to flash this new bootloader version.
|
November 9th, 2017
|
0.8.12 / 0.8.11
|
10601
|
Public beta release
|
[5]
|
Hotfix release:
- Device Gain is again calculated correctly. It had been removed by mistake.
- Torque command update rate has been increased to 2500 Hz. Beginning from early version 0.5.0, it was reduced to 1250 Hz, to overcome unrelated issue, which was then forgotten until now.
|
November 9th, 2017
|
0.8.11 / 0.8.11
|
10601
|
Public beta release
|
[6]
|
New features:
- These DirectInput effects and features have been implemented that were not previously implemented: Friction, Damping, Device Gain
- Sliders to set general strength multiplier for friction and damper have been added into the UI
- Device gain is being set when a game starts, so no slider for it is required in the UI.
- Previously exported simucubeprofiles.ini file with these settings missing will load. The DirectInput Friction and Damping gains will be set at 50% for those profiles.
- Saved setting on SimuCUBE flash memory have 0% setting for these. User must change them manually to some sensible value for each profile.
- Games tested: Assetto Corsa, Dirt Rally, Automobilista (Pure FFB no effects is supported; effects -settings might not work correctly)
- New Tabbed UI with much more refined looks
- Tabs!
- Effect types are shown in the UI, with bolded font for those effects that game is changing actively
- Button has been added to clear effect memory and reset Device Gain. This is useful when game has crashed and left effects running.
- Motor fault reason codes are being read and shown directly in the user interface. However, faults are cleared if they ever happen, so the indicator will disappear too soon. Usefulness of this feature is going to be improved in the next release.
- Confirmation dialog for profile deletion has been added.
- Lots of other small tidy-ups and fixes
Bug fixes:
- Importing analog axis settings from the .ini file didn't load invert axis -settings correctly.
Known issues:
- Estimated torque output calculation is stll likely wrong.
- When using high forces and having the reconstruction filter at high value, the wheel might go numb and give a feeling of saturated forces. This is being investigated.
|
October 25th, 2017
|
0.8.4 / 0.8.4
|
10601
|
Public beta release
|
[7]
|
Changes and fixes:
- Strength setting of the default profile was not applied at startup.
- Read-only safe profile was applied inconsistently when running the Motor Configuration Wizard
- SimuCUBE Hardware Revision information is now shown in the configuration tool
- Removed unnecessary code and USB debug counter
- Clicking Toggle IONI USB Configuration -button does not reset all motor faults, only the Simplemotion faults.
Known issues:
- Estimated torque output calculation is stll likely wrong.
- When using high forces and having the reconstruction filter at high value, the wheel might go numb and give a feeling of saturated forces. This is being investigated.
|
October 13th, 2017
|
0.8.3 / 0.8.3
|
10601
|
Public beta release
|
[8]
|
Changes and fixes:
- Serious USB issue is fixed. Replies to USB control requests weren't getting sent to PC if SimuCUBE was already in the process of sending a normal HID report. This caused crashes in games.
Known issues:
- Estimated torque output calculation is most likely wrong.
- When using high forces and having the reconstruction filter at high value, the wheel might go numb and give a feeling of saturated forces. This is being investigated.
- Some filter settings do not seem get applied with some user actions.
|
October 8th, 2017
|
0.8.2 / 0.8.2
|
10601
|
Public beta release
|
[9]
|
Notes:
- Unfortunately, this version will clear all profile settings. Please take note of all your settings.
- Note: Updates do not have effect on the parameters that are stored on IONI drive, so no new drc configuration files should be needed.
- Precautions have been made to minimize this being required in the future.
New features:
- Profiles can be saved into simucubeprofiles.ini file and imported from that file. Imported profiles are added, they will not overwrite user's profiles. Feature has an indicator for successful loading and saving.
- Force scaling (in percentage) is done by setting MMC on IONI drive instead of scaling the torque that goes to drive. This increases the fidelity. NOTE: To change maximum MMC, upload a new DRC file with new setting using the motor configuration wizard, or use Granity to set new MMC.
- Motor configuration wizard has a field for Motor Torque Constant. If it is set, configuration tool assumes 48 V power supply, reads motor resistance from current IONI configuration, and shows maximum torque value in the UI.
Changes and fixes:
- Analog button debounce time has been increased from 10 ms to 20 ms. Setting for this might be added in the future.
- Analog axis settings import/export now has an indicator for success/failure.
- Analog axis averaging has been changed from average of last 32 values to average of last 32 values but disregarding 4 highest and 4 lowest values to improve signal quality.
- Steering centering offset value was not saved correctly if the index point was sufficiently off-center (more than 65535 counts offset). This was evident on high-resolution encoders.
- Maximum number of profiles has been reduced to 500.
- Game-induced torque could easily overcome the bumbstop effect's torque, making the wheel spin uncontrollably. This has been fixed.
- Damping filter was being sent to IONI with setting of 0.0 % if game set a damping effect. This was unintended, and has been changed for this version. On-the-fly changing damping, inertia and friction effects are not being done currently.
- Improved resiliency against non-communicating IONI drives. This could happen if, for whatever reason, the SMO Bus Address Offset was other than 0, and the drive was still functional when using MMos firmware.
- Improved/fixed some subdialogs to work better with high-DPI displays or when display has a custom scaling factor.
- Enabling IONI USB communication mode does not cause a SimpleMotion error / Fault in the IONI drive anymore.
Known issues:
- USB-related game crash issues
- Estimated torque output calculation is most likely wrong.
|
September 19th, 2017
|
0.7.1 / 0.7.5
|
10601
|
Public beta release
|
[10]
|
Changes and fixes:
- Some profile settings were being set to default when running the firmware update wizard
- Ioni filter parameters are no longer being read to the active profile, overwriting the profile values, when running the motor configuration wizard
- Changed TBW to 1000Hz as default for all new profiles and also for the default read-only profile.
- Minor text changes in firmware update wizard
|
|
0.7.0 / 0.7.3
|
10601
|
Closed beta release
|
not public
|
New features:
Bug fixes:
- Profile name did not get applied and saved if only profile name was edited
- Configuration tool crashed if user canceled or finished the Firmware Update wizard
|
|
0.7.0
|
10601
|
Closed beta release
|
not public
|
New features:
- Working digital button inputs
- Profile management
- Analog settings .ini-file import/export
Bug fixes:
- Settings change by some amount at saving or load from IONI drive.
|
|
<0.7.0
|
|
Closed beta release(s)
|
not public
|
No change history for these early firmware releases.
|
IONI firmware
As SimuCUBE requires an IONI Servo & Stepper Drive, it is recommended to keep the on-board IONI firmware at latest release. SimuCUBE firmware has the IONI firmware bundled in, and the IONI firmware will be automatically updated if the current IONI firmware on the drive is too old. For manual firmware updates, see IONI firmware releases and Granity user guide/Uploading a firmware.
Motor configuration files for Granity (.drc)
See List of motors for SimuCUBE for sample configuration settings & files for various SimuCUBE compatible motors.
| This page is work in progress state. Do not use any of this information until this notice has been removed. |
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.