Torque controller tuning means finding the correct gain values for a torque controller inside the servo drive to achieve a proper response from a torque setpoint change.

In Granity, there is no dedicated PI gains as the software supports entering motor coil inductance and resistance where the optimum PI gains are calculated from. In order to change torque tuning, one needs to change motor resistance [MR] and inductance [ML] parameters until the torque response looks satisfactory.

Preparations

Correct torque tuning settings on the Testing tab.

Steps to do to begin torque tuning:

  • Ensure that motor is parameterized correctly and working
  • Fix the motor shaft so that it cannot rotate under full peak torque of the motor
  • Make following parameter changes to Granity and click apply afterwards:
    • Set drive in torque control mode [CM]
    • Set torque bandwidth limit [TBW] to maximum
    • Choose Serial only setpoint input [CM]
    • Make other necessary adjustments to have drive powered and enabled
  • Set-up the test stimulus and capture settings from Testing tab:
    • Set target setpoint 1 [TSP1] to 5000-15000
    • Set delay 1 [TSD1] to 0.05 seconds
    • Set target setpoint 2 [TSP2] to 0
    • Set delay1 [STD2] to 0.5 s
    • Choose sample rate [TSR] of 10000 Hz or more
    • Choose Capture setpoint change ind positive direction from the dropdown
    • Tick Continuously repeating capture
    • Tick Torque setpoint and Torque achieved from signals
    • Tick Start capture to begin continous capture.
    • Tick Enable test stimulus [TSE] to begin a pulsed torque generation

Once the steps above are done, motor should be generating short torque pulses to a fixed shaft and torque response graphs should appear on the right side of Granity about once in 3-5 seconds.

Adjusting MR and ML to for optimum torque control

The task here is to adjust the [MR] and [ML] parameters to achieve near optimum step response for the torque controller. Observe the images below for guidance.

If the drive faults during this testing due to overcurrent, try reducing [STP1] value or increase fault current tolerance [FOC] parameter, click Apply, and clear drive faults via the Connect tab.

TorqlowR.png

In this case the resistance [MR] value has been set too low causing slowly rising achieved torque curve. Such slow response would reduce servo responsiveness.

TorqhighR.png

In the opposite case (too high [MR] value) the response shows wavy oscillations and ovesrhoot.

TorqlowL.png

Same kind of phenomenon will be seen if motor inductance [ML] value is too low. Finding oscillation free tuning is finding the correct balance between the MR and ML as both affect each other.

TorqhigL.png

Too high inductance [ML] will cause sharp overshooting and high frequency oscillations. Motor may produce audible noise if oscillations are continuous (occurs with way too high ML).

Torqgood.png

The above image shows near optimum torque response with fast rising edge combined to minimal overshoot.

Torqgoodspinning.png

The above image shows what may happen if motor shaft is not fixed properly (allowed to rotate). This is withe the optimum settings like the previous image.

Steps to do after tuning finished

  • Stop test stimulus by unticking [TSE]
  • Stop scope catpure by unticking Continuously repeating capture
  • Undo all temporary changes made to settings (such as [TBW] and [CM]) but leave the optimized [MR] and [ML] values active
  • Save settings to drive memory by clicking Save settings on drive non-volatile memory button

In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.