Fault location
Fault location ID 1 & 2 that are displayed on Granity Testing tab Device state section. Fault locations are detailed numeric codes giving a hint what was the precise reason causing a fault state.
List of Fault location ID 1
Fault location ID 1 | Reason | Solution |
---|---|---|
1-2 | Current sensing range exceeded | See solutions of 120 and 600. |
100,110,200,220,2100-2126 | Loading or saving settings in drive memory failed | Programming error, contact developers |
120 | Short circuit protection triggered (very high & fast current rise detected) | Check wiring for shorts, ensure that motor inductance is sufficient (especially ironless & pancake motors), perform Tuning position controller, adjust FOC. |
600 | Overcurrent protection triggered (slower reaction but lower current level than short circuit protection) | Check wiring for shorts, ensure that motor inductance is sufficient (especially ironless & pancake motors), perform Tuning position controller, adjust FOC. |
2050 | Attempted to set fault bit active in clear faults function | Programming error, contact developers |
2320-2321,2330,2340 | Communication error between GraniteCore processors | Contact Granite Devices if problem repeats |
3001 | Hall sensors are enabled but no valid signals present (all hall inputs 0's or 1's which is illegal state) | Check wiring and settings |
3060 | Power stage fault signal active (possible overtemperature, logic circuit undervoltage, Safe torque off | Contact Granite Devices if problem repeats |
5500 | Motor type MT not selected | Choose MT |
5501 | Unsupported motor type MT not selected | Choose MT |
6601 | Phasing a.k.a. phase search failed | Check motor settings, wiring and supply voltage |
6602 | Phasing a.k.a. phase search failed due to both limit switches being open | Check limit switch settings and switch operation |
9996-9999 | Internal range check of internal variable failed | Programming error, contact developers |
List of Fault location ID 2
The list is incomplete. In case of other errors, contact Granite Devices support.
Fault location ID 2 | Reason | Solution |
---|---|---|
100202 | GraniteCore status update failed | Programming error, contact developers |
600101-600106 | GraniteCore connection failed | Programming error, contact developers |
480301 | Extracting payload from SMV2 packet failed | Check SMV2 communication |
480501 | SMV2 buffer overflow | SMV2 application error |
480502 | SMV2 command corrupted because it has overflown payload buffer size | SMV2 application error |
480503 | SMV2 return data buffer overflow | SMV2 application error |
480601 | Invalid SMV2 command | SMV2 application error |
480901 | SMV2 communication timeout | SMV2 application error |
480801 | Invalid SMV2 SMP packet type | SMV2 application error |
480901 | SMV2 packet CRC error | Communication error |
710301 | Command queue to GraniteCore full | Programming error, contact developers |
200101-200801 | I/O side CPU error interrupt triggered | Programming error or hardware issue (supply voltage? EMI?) |
100101 | Reading init state from GraniteCore failed | Programming error, contact developers |
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.