This is the intallation & user guide for the Intensify Nx50 laser diode driver. Read it through before operating the device.
In case of any questions, please don't hesitate to contact us.
Contents
Physical installation and cooling
Nx50 should be mounted inside an enclosure by using spacer feet attached to the four corner holes.
Nx50 has low power losses due to highly efficient multiphase switching converter technology. Power loss can be calculated by using the offered efficiency data as setpont.
In most cases Nx50 is sufficiently cooled with natural convection. This is best achieved by mounting boards vertically and leaving at least 25 mm free air space around both sides.
However, if natural convection does not offer sufficient cooling (i.e. if peak surface temperature is near or exceeds 100°C), then forced convection is necessary. This can be achieved by placing a fan or blower on the side of PCB so that air flow passes along board surface.
Wiring
J1 connector
J1 connector is the user side I/O of the driver. This connector contains the control and feedback signals. All signal lines of the port are ESD protected by dedicated suppressors.
Mating connector type is a 10 pin flat ribbon cable connector with 0.1"/2.54 mm pin pitch and a polarity key. See spec sheet of compatible connector here.
J1 pin out
Pin # | Signal name | Direction | Signal description | Impedance vs GND |
---|---|---|---|---|
1 | PULSE | In | Pulse control:
|
10 kOhm |
2 | GND | I/O and Analog ground | 0 Ohm | |
3 | IMON | Out | Current monitor 0-10 V analog output | 1 kOhm |
4 | GND | Out | I/O and Analog ground | 0 Ohm |
5 | VMON | Out | Voltage monitor 1:1 analog output | 1 kOhm |
6 | GND | Out | I/O and Analog ground | 0 Ohm |
7 | ISET+ | In | Current setpoint 0-10 V positive input (differential) | 51 kOhm |
8 | ISET- | In | Current setpoint 0-10 V negateive input (differential) | 51 kOhm |
9 | ENABLE | In | LDD enable:
|
6.6 kOhm |
10 | GND | I/O and Analog ground | 0 Ohm |
Impedances
When driving an J1 input pin, the source impedance of controller should be significantly lower than input impedance of the corresponding pin. I.e. if input impedance is 51 kOhm, then recommended source impedance is less than 5 kOhm max, preferrably 0.5 kOhm. Lower source impedance yields lower voltage drop error.
Also when an output of J1 is connected to the input of controller, the controller input impedance should be significantly higher than J1 pin impedance. I.e. when connecting VMON (1 kOhm) to analog input or ADC, the controller input impedance should be at least 10 kOhm. However all outputs are short circuit proof and input impedance recommendation affects only monitor accuracy.
See impedance column of pin out table
Digital signals
All digital signals (PULSE & ENABLE) are referenced to GND and applicable voltage levels are:
State | Voltage range |
---|---|
Logic LOW | -0.3 .. 0.6V |
Logic HIGH | 3.0 - 26 V |
Analog signals
Analog input signal support differential signaling to cancel noise and ground loop induced error. These are designed to be compatible with another differential source as well as single ended systems. The differential signals allow up to +/- 1.5V difference on ground reference potentials between Nx50 and controller without losing accuracy.
Connection to differential 0-10V analog I/O:
Controller | J1 signal |
---|---|
Analog in 1 + | IMON |
Analog in 1 - | GND |
Analog in 2 + | VMON |
Analog in 2 - | GND |
Analog out 1 + | ISET+ |
Analog out 1 - | ISET- |
Ground | GND |
Connecting to single ended 0-10V analog I/O. Assuming that I/O is referenced to Ground.
Controller | J1 signal |
---|---|
Analog in 1 | IMON |
Analog in 2 | VMON |
Analog out 1 | ISET+ |
Ground | ISET- |
Ground | GND |
Power
A regulated 12VDC power supply should be connected to hole terminals labeled GND and +12V. Required power is nearly directly proportional to output power plus losses.
For example outputting 40A to 2.0V diode equals output power of 80W. With losses the needed power is about 85-90W which equals 7.0-7.5A @ 12V.
Laser diode
Laser diode is connected to hole terminals labeled O+ and O-. O+ goes to LD anode and 0- to cathode.
Connecting parallel
Nx50 boards may be connected parallel simply by connecting all power and I/O lines parallel pin-by-pin basis.
This can be achieved by stacking them by using metallic standoffs to form conductive path between O+, O-, GND, and +12V terminals. Use M4 or M5 threaded standoffs with minimum height of 16 mm.
J1 connector may be paralleled by inserting multiple 10 pin IDC connectors to the single ribbon cable. By this method all J1 pins are properly connected parallel pin-to-pin basis.
Usage
The device starts operating instantly after powered and and proper signals fed to J1 pins. No other initialization is needed.
CW usage
- Mandatory connections
- LD connected between O+/O-
- 12VDC supply connecter between +12V/GND
- J1 connector pins:
- GND connected to controller's ground reference:
- 0-10V current setpoint signal fed to ISET+/ISET-
- ENABLE set to HIGH or tied to GND
- Optional J1 connections
- IMON wired to analog input
- VMON wired to analog input
- PULSE set to HIGH or left open
Pulsed usage
For pulsed usage it is recommended to use PULSE input or modulate the ISET analog voltage. It is not recommended to set current to 0 during off-periods for to achieve faster pulse rise times and zero overshoot. Recommended bias current during off-periods is 2-10% of current setpoint.
- Mandatory connections
- LD connected between O+/O-
- 12VDC supply connecter between +12V/GND
- J1 connector pins:
- GND connected to controller's ground reference:
- 0-10V current setpoint signal fed to ISET+/ISET-
- ENABLE set to HIGH or tied to GNDA
- PULSE set pulse source. Logic LOW means 100% of set current and HIGH reduces output current to 3.5% (bias current to allow faster rise time)
- Optional J1 connections
- IMON wired to analog input
- VMON wired to analog input
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.