Argon specifications overview table

From Granite Devices Knowledge Wiki
Revision as of 00:27, 16 February 2015 by Tero K (Talk | contribs)


Jump to: navigation, search
Function Description
Servo motor drive Closed loop control of various types of servo motors by sinusoidal field oriented control with dead-time distortion correction and high dynamic range torque control.
  • Support over 97% of all the servo motors below 2 kW in the market
  • Synchronous AC & BLDC motors
    • Sinusoidal and trapezoidal commutated
    • SPM (Surface Permanent Magnet) and IPM (Internal Permanent Magnet) types
  • Brush DC motors
  • Linear motors
    • Iron core
    • Ironless (with external inductive filter)
Control modes
  • Torque control
  • Velocity/speed control
  • Position control
Setpoint types

See setpoint signal / reference inputs list

Closed loop Cascaded control loops (PIV):
  • Torque / current control, update frequency 17.5 kHz
  • Velocity control, update frequency 2.5 kHz
  • Position control, update frequency 2.5 kHz

Dual-loop feedback support planned as firmware upgrade

Feed-forwards Feed-forwards working in velocity & position control modes:
  • Acceleration (inertia canceling) feed-forward
  • Velocity (friction canceling) feed-forward
Homing Integrated homing function for position control mode:
  • Sensorless hard-stop homing
  • Home switch search
  • Index pulse search
  • Soft position limits (eliminate limit switches)
Feedback devices See feedback devices list
Safety
  • Safe torque off with 3-way redundancy
  • Stopping motor on errors
    • Tracking error (velocity & position)
    • Over speed error
    • Limit switch
  • DC motor runaway prevention on feedback loss
  • Communication error detection
Protections
  • Over current
  • Short circuit (phase-to-phase)
  • I2t motor thermal protection
  • Over & under voltage
  • Over temperature
Power supply

Two power supply methods:

  • Integrated AC mains power supply: single phase 85 – 264 VAC 50/60 Hz, 0 – 16 A
  • Externally supplied 40 – 380 VDC
  • Additionally an external 24 VDC logic supply required
Motor output current
Commissioning
Compliance CE (LVD & EMC): EN 61800-5-1:2007 and IEC 61000-6-1:2005

In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.