Argon firmware 2.0 public beta
Argon servo drive firmware version 2.0 public beta is available for evaluation.
The key changes singe 1.4.0 are:
- New features:
- Added Position feed-forward gain parameter PFF - helps to reduce overshoot in position control mode. In previous firmware, this value was fixed to 100%.
- Simulated encoder output from internal EXT connector (6 pin header) - useful with resolver systems where external controller needs encoder count
- Homing with index pulse search is now possible with resolver feedback device (simulated index pulse at certain resolver angle(s))
- Added Torque mode application specific attributes (rotation angle limit & torque scaling by analog input)
- Added support for direction input signal in PWM and Analog setpoint modes
- SimpleMotion V2 protocol updated:
- added support for watchdog (stop drive if valid SM commands not arriving within predefined time period)
- calculation of setpoint commands via SM bus renewed (drive setpoint is a sum of phyiscal setpoint (step/dir, pwm, analog etc) and the setpoint from SM host (instant and buffered commands). If SM host sets absolute setpoint, then phyiscal counter (incremental types onle) are reset to zero.)
- in buffered command execution, now only writing to setpoint commands consume user defined time and all other commands are executed as fast as possible (i.e. now possible to modify parameters on the fly while buffered motion is running)
- Improvements:
- Increased continuous current output limit from 11A to 12.5A and peak current limit from 16A to 18A
- Increased maximum overvoltage level from 382 VDC to 388 VDC
- Support high encoder resolution encoder (up to 4 000 000 PPR, previously was 65 535 PPR)
- Added new torque bandwidth limit choices: 4700 Hz and Unlimited
- Increased Phasing a.k.a. phase search algorithm motor swing to allow successful phasing in the case where motor motion is blocked in one direction
- Increased speed of Phasing a.k.a. phase search
- Improve fault tolerance with Resolver feedback device
- Added compatibility for Granity 1.7.0 and later
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.