Tuning torque controller

From Granite Devices Knowledge Wiki
Revision as of 17:32, 21 October 2015 by Tero K (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Jump to: navigation, search

Torque controller tuning means finding the correct gain values for a torque controller inside the servo drive to achieve a proper response from a torque setpoint change.

Direct inductance & resistance setting method[edit | edit source]

In Granity, there is no dedicated torque control PI gains as the software supports entering motor coil inductance and resistance where the suitable PI gains are calculated from.

Method 1 (preferred)[edit | edit source]

If you are using a drive model that supports automatic measurement of inductance and resistance, follow the instructions here.

Method 2[edit | edit source]

If the above measurement function is not available, and your motor comes with coil specifications containing phase-to-phase inductance and resistance values, then the only necessary step is to enter the given values into motor Coil resistanceMR and Coil inductanceML parameter fields. In case of troubles with this method, proceed with manual tuning method.

Manual tuning method[edit | edit source]

Manual tuning of torque controller is some times done in order to optimize the torque controller response or to find the correct motor Coil resistanceMR and Coil inductanceML parameters if unknown. Manual tuning also usually yields better torque response than the direct method which may help tuning of velocity or position tuning.

In order to change torque tuning, one needs to change motor Coil resistanceMR and Coil inductanceML parameters until the torque response looks satisfactory.

Preparations[edit | edit source]

Correct torque tuning settings on the Testing tab.

Steps to do to begin torque tuning:

  • Ensure that motor is parameterized correctly and working
  • Fix the motor shaft so that it cannot rotate under full peak torque of the motor
  • Make following parameter changes to Granity and click apply afterwards:
    • Set drive in torque control mode Control modeCM
    • Set Torque bandwidth limitTBW to maximum
    • Choose Serial only setpoint input Control modeCM
    • Untick Setpoint smoothingCIS
    • Set Goals tab Setpoint dividerDIV and Setpoint multiplierMUL to 50
    • Make other necessary adjustments to have drive powered and enabled
  • Set-up the test stimulus and capture settings from Testing tab:
    • Set target setpoint 1 TSP1 to 2000-15000 (see the chapter below for finding the optimum test setpoint)
    • Set delay 1 TSD1 to 0.05 seconds
    • Set target setpoint 2 TSP2 to 0
    • Set delay1 TSD2 to 0.5 s
    • Choose sample rate Sample rateTSR of 10000 Hz or more
    • Choose Capture setpoint change ind positive direction from the dropdown
    • Tick Continuously repeating capture
    • Tick Torque setpoint and Torque achieved from signals
    • Tick Start capture to begin continous capture.
    • Tick Enable test stimulusTSE to begin a pulsed torque generation

Once the steps above are done, motor should be generating short torque pulses to a fixed shaft and torque response graphs should appear on the right side of Granity about once in 3-5 seconds.

Finding optimium test current (TSP1)[edit | edit source]

To find optimum value for TSP1, enable capture channel called "Motor output voltage" to see how much voltage is driven to motor during rising the edge of torque. For optimum TSP1 value the voltage peak should lie within 20% to 80%. If voltage gets saturated (100%), reduce TSP1 value until it stays below 80%. Images below illustrate the wrong case (first image) and correctly set case (second image).

Adjusting MR and ML to for optimum torque control[edit | edit source]

The task here is to adjust the Coil resistanceMR and Coil inductanceML parameters to achieve near optimum step response for the torque controller. Observe the images below for guidance.

TorqlowR.png

In this case the Coil resistanceMR value has been set too low causing slowly rising achieved torque curve. Such slow response would reduce servo responsiveness.

TorqhighR.png

In the opposite case (too high Coil resistanceMR value) the response shows wavy oscillations and ovesrhoot.

TorqlowL.png

Same kind of phenomenon will be seen if motor Coil inductanceML value is too low. Finding oscillation free tuning is finding the correct balance between the MR and ML as both affect each other.

TorqhigL.png

Too high Coil inductanceML will cause sharp overshooting and high frequency oscillations. Motor may produce audible noise if oscillations are continuous (occurs with way too high ML).

Torqgood.png

The above image shows near optimum torque response with fast rising edge combined to minimal overshoot.

Torqgoodspinning.png

The above image shows what may happen if motor shaft is not fixed properly (allowed to rotate). This is with the same optimum settings like the previous image.

Steps to do after manual tuning finished[edit | edit source]

  • Stop test stimulus by unticking Enable test stimulusTSE
  • Stop scope catpure by unticking Continuously repeating capture
  • Undo all temporary changes made to settings (such as Torque bandwidth limitTBW, Control modeCM, Setpoint dividerDIV, Setpoint multiplierMUL) but leave the optimized Coil resistanceMR and Coil inductanceML values active
  • Save settings to drive memory by clicking Save settings on drive non-volatile memory button

Using drive in torque mode[edit | edit source]

If torque mode is the final desired operating mode, set-up the setpoint signal source from Granity Goals tab. Also see Signal path of motor drive for explanation of torque setpoint scale.



In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.