250 Watt 82 ohm regenerative resistor suitable for Argon drive

Regenerative resistors are usually a required part with servo drives to absorb returned energy from decelerating or braking servo axis.

Servo drive with motor can act two ways: energy supply and energy generator. The generator behavior occurs during decelerations and this causes current flow from motor to drive power supply capacitors. If that generated energy is not absorbed anywhere, the voltage of capacitors will rise above overvoltage threshold and trigger an software clearable overvoltage fault.

Argon supports connecting braking resistor directly to drive J4 connector.

Suitable resistor type

Recommended resistor specifications:

  • Resistance 80-100 ohms
  • Power rating 150-300 Watts
  • Wire wound construction (no film resistors)
  • Preferrable in metal housing for grounding/noise shielding

The 250W resistor in the image can absorb enough peak energy to stop 100 kg mechanical linear axis moving up to 3 m/s.

Example of suitable resistor: Tyco HSC 250 82R. Data sheet

Installation

Wiring of braking resistor to Argon drive

The image above shows proper wiring of braking resistor. Proper installation has:

  • Shielded cable with 3 conductors with wire gauge at least 0.75 mm² / 18 AWG
  • Cable shield AND earth conductor connected to drive PE terminal
  • Earth conductor connected to resistor casing. Place toothed locking washers between wire terminal and resistor to break the insulating coating of resistor case.
  • Two other conductors connected to resistor terminals through 8A fast blow fuse
  • Resistor should be also mounted on heat sink
  • Additionally it is a recommended to shield the resistor terminals from accidental touching
float

DANGER the terminals of the resistors are connected to dangerous voltages. Never touch them before drive power has been safely discharged.


In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.