Connecting a protective earth to Argon drive is the most crucial single connection to be made. Argon has two earthing methods:
 
Connecting a protective earth to Argon drive is the most crucial single connection to be made. Argon has two earthing methods:
 
*'''Earthing through the J4 PE terminal''' (always required)
 
*'''Earthing through the J4 PE terminal''' (always required)
*'''Earthing the device case''' (highly recommended and may be required by regulations in some countries)
+
*'''Earthing the heat sink''' (always required)
 +
*'''Earthing the device case''' (always required)
  
 
{{electricshock|Supplying power to the drive '''without proper earthing''' will allow leakage current to raise voltage potential of the device case to hazardous levels. Also ELV circuits (the other ports than J4) may become hazardous without earthing.}}
 
{{electricshock|Supplying power to the drive '''without proper earthing''' will allow leakage current to raise voltage potential of the device case to hazardous levels. Also ELV circuits (the other ports than J4) may become hazardous without earthing.}}
Line 17: Line 18:
 
After wiring, verify electrical connection by using a resistance meter between the case PE wire and J4 PE terminal while J4 PE wire is not connected.
 
After wiring, verify electrical connection by using a resistance meter between the case PE wire and J4 PE terminal while J4 PE wire is not connected.
  
[[category:Argon user guide]]
+
[[Category:Argon_user_guide]]

Revision as of 10:23, 5 March 2020

Connecting a protective earth to Argon drive is the most crucial single connection to be made. Argon has two earthing methods:

  • Earthing through the J4 PE terminal (always required)
  • Earthing the heat sink (always required)
  • Earthing the device case (always required)


Earthing through the J4 PE terminal

This is a mandatory connection. Follow the Argon wiring instructions.

Earthing the device case

Earthing points of the case
Proper earthing wire installation with toothed locking washers ensure an electrical contact through surface coatings.
Attaching protective earth wire to the case can provide much lower impedance PE connection compared to the J4 terminal making it highly recommended addition to grounding through J4. Using both of the methods provides redundancy in the case of one method fails.

Parts needed:

  • 1pcs wire ring terminal with 4-5.5 mm hole with at least 20 Ampere capable earthing conductor
  • 2pcs M4 serrated/toothed lock washers
  • 1pcs M4 screw, 6-8 mm thread length

Verifying connection

After wiring, verify electrical connection by using a resistance meter between the case PE wire and J4 PE terminal while J4 PE wire is not connected.