Editing Commissioning of KANZ servo motors
Your changes will be displayed to readers once an authorized user accepts them. (help) |
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 22: | Line 22: | ||
#Download KANZ motor configuration files: [[Media:KANZ Argon base settings.zip]] | #Download KANZ motor configuration files: [[Media:KANZ Argon base settings.zip]] | ||
#Connect drive to Granity ([[Argon_user_guide/Making_the_first_Granity_connection|instructions]]) | #Connect drive to Granity ([[Argon_user_guide/Making_the_first_Granity_connection|instructions]]) | ||
− | #Click ''Load settings from file'' and open corresponding configuration file | + | #Click ''Load settings from file'' and open corresponding configuration file |
#Click ''Save settings on drive non-volatile memory'' and if choose Apply and Restart drive buttons in the dialogs that may appear | #Click ''Save settings on drive non-volatile memory'' and if choose Apply and Restart drive buttons in the dialogs that may appear | ||
#After drive restarts, connect again to drive and review all settings. For first testing safety it is recommended to reduce current limits {{param|MMC}} and {{param|MCC}} to a lower value (such as 20% of rated values) in order to limit motor torque if unexpected motion takes place. Also set control mode {{param|CM}} as required by end application. | #After drive restarts, connect again to drive and review all settings. For first testing safety it is recommended to reduce current limits {{param|MMC}} and {{param|MCC}} to a lower value (such as 20% of rated values) in order to limit motor torque if unexpected motion takes place. Also set control mode {{param|CM}} as required by end application. | ||
Line 29: | Line 29: | ||
{{tip|Pre-made motor configuration files may have significantly different motor resistance {{param|MR}} and inductance {{param|ML}} values compared to motor data sheet. Pre-made files are hand-optimized to give better performance than entering values from data sheet, so it is recommended to leave these values untouched.}} | {{tip|Pre-made motor configuration files may have significantly different motor resistance {{param|MR}} and inductance {{param|ML}} values compared to motor data sheet. Pre-made files are hand-optimized to give better performance than entering values from data sheet, so it is recommended to leave these values untouched.}} | ||
− | |||
− |