Editing Intensify Nx50
Your changes will be displayed to readers once an authorized user accepts them. (help) |
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 3: | Line 3: | ||
| image = [[Image:nx50single.JPG|280px]] | | image = [[Image:nx50single.JPG|280px]] | ||
| controlmodes = Current control | | controlmodes = Current control | ||
− | | production = | + | | production = In production & available from stock |
| voltage = 12 ± 1 VDC | | voltage = 12 ± 1 VDC | ||
| currentrange = 0.1 - 50A × number of stacked boards | | currentrange = 0.1 - 50A × number of stacked boards | ||
Line 14: | Line 14: | ||
| other_data=0.8 .. 5.0 VDC | | other_data=0.8 .. 5.0 VDC | ||
| other_label2=Ripple current (typ @ 50A) | | other_label2=Ripple current (typ @ 50A) | ||
− | |||
| other_data2=0.2A RMS, 1.25A pk-pk | | other_data2=0.2A RMS, 1.25A pk-pk | ||
}} | }} | ||
Line 50: | Line 49: | ||
| Output current || 0 - 50 <sup>(1)</sup>|| A || Continuous rating | | Output current || 0 - 50 <sup>(1)</sup>|| A || Continuous rating | ||
|- | |- | ||
− | | Efficiency || | + | | Efficiency || 95 ||% || Efficiency when I<sub>O</sub> > 20A and V<sub>O</sub> = 5V |
|} | |} | ||
(1) For single Nx50 board. Multiply this by the number of stacked Nx50 boards. | (1) For single Nx50 board. Multiply this by the number of stacked Nx50 boards. | ||
Line 67: | Line 66: | ||
| Disable delay || < 2 || ms || From enabled to disabled state | | Disable delay || < 2 || ms || From enabled to disabled state | ||
|- | |- | ||
− | | Power-up/down sequence || | + | | Power-up/down sequence || Any order. Any I/O line states not causing spiking above setpoint || || |
|- | |- | ||
|} | |} | ||
===Inputs/outputs=== | ===Inputs/outputs=== | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 97: | Line 89: | ||
| Enable input voltage || | | Enable input voltage || | ||
*Logic LOW: -0.3..0.6 V or open circuit = disabled | *Logic LOW: -0.3..0.6 V or open circuit = disabled | ||
− | *Logic HIGH: | + | *Logic HIGH: 3..26 V = enabled |
− | || V || Enable is 5V, 12V and 24V logic compatible | + | || V || Enable is 3.3V, 5V, 12V and 24V logic compatible |
|- | |- | ||
| Pulse input voltage || | | Pulse input voltage || | ||
*Logic LOW: -0.3..0.6 V or open circuit (I<sub>O</sub>=100% of setpoint) | *Logic LOW: -0.3..0.6 V or open circuit (I<sub>O</sub>=100% of setpoint) | ||
− | *Logic HIGH: | + | *Logic HIGH: 3..26 V (I<sub>O</sub>3.5% of setpoint) |
− | || V || Pulse is 5V, 12V and 24V logic compatible. | + | || V || Pulse is 3.3V, 5V, 12V and 24V logic compatible. Pulse high outputs current defined by [[setpoint]], pulse low outputs current 0.035*setpoint. |
|} | |} | ||
(1) For single Nx50 board. Multiply this by the number of stacked Nx50 boards.<br /> | (1) For single Nx50 board. Multiply this by the number of stacked Nx50 boards.<br /> | ||
Line 125: | Line 117: | ||
|ESD protection|| Exceeds ESD Protection to IEC61000-4-2 Level 4, ±12 kV discharge||||All I/O lines | |ESD protection|| Exceeds ESD Protection to IEC61000-4-2 Level 4, ±12 kV discharge||||All I/O lines | ||
|} | |} | ||
− | |||
− | |||
− | |||
==Setup guide== | ==Setup guide== | ||
* [[Intensify Nx50 setup guide|Intensify Nx50 setup & user guide]] | * [[Intensify Nx50 setup guide|Intensify Nx50 setup & user guide]] | ||
− | |||
− |