Intensify Nx50

From Granite Devices Knowledge Wiki
Revision as of 12:39, 7 June 2014 by Tero K (Talk | contribs)


Jump to: navigation, search

Intensify Nx 50 is a stackable constant current laser diode bar driver featuring the latest multiphase switched-mode topology delivering up to 50A continuous current at unforeseen efficiency. Parallel capability allows stacking multiple Intensify boards to scale up the current up to 150A. Intensify is intended for OEM applications such as fiber laser pumping, laser tooling and laser diode burn-in.

Intensify Nx50
280px
Device type Laser diode driver
Control modes Current control
Status In production & available from stock
Electrical
DC supply voltage 11-13 VDC
Output current range 0.1 - 50A × number of stacked boards
Setpoint signals Analog reference for current control, Digital signals for enable & pulsing
Feedback devices On-board current & voltage sensing
Protections Over temperature, under voltage, short circuit, laser diode protection
LD forward voltage 0.8 .. 5.0 VDC
Ripple current (typ @ 50A) 0.2A RMS, 1.25A pk-pk
General
Dimensions 94×77.5×17 mm
Configuration tool No software tools needed
Web site

Intensify product site

Technical specifications

Power

Property Value Units Remarks
Supply voltage 12 +/- 1 V
Supply current 0.1 - 24 A Depends on output power
Max output power 250 W 50A @ 5.0V
Output voltage 0.8 - 5.0 V Determined by laser diode voltage drop
Output current 0 - 50 A Continuous rating
Efficiency 95 % Efficiency when Io > 20A and Vo > 5V

Time properties

Property Value Units Remarks
Pulsed LD current rise time 0.5 typ ms Current rise from 10% to 90% of setpoint
Pulsed LD current rise time 0.6 typ ms Current fall from 10% to 90% of setpoint
Enable delay < 60 ms From disabled to enabled state
Disable delay < 2 ms From enabled to disabled state
Power-up/down sequence  Any order. Any I/O line states not causing spiking above setpoint

Inputs/outputs

Property Value Units Remarks
Current setpoint voltage 0..10 V 0..10 V sets LD current between 0..50 A
Current setpoint input impedance 50k Ω Differential input
Current monitor output voltage 0..10 V 0..10 V represents LD current between 0..50 A
Current monitor output impedance 200 Ω
Voltage monitor output voltage 0..5.5 V Represents LD voltage drop 1:1
Voltage monitor output impedance 200 Ω
Enable input voltage
  • -0.3..1 V or open circuit = disabled
  • 2.5..13 V = enabled
V Enable is 3.3V, 5V and 12V logic compatible
Pulse input voltage
  • -0.3..1 V or open circuit = pulse high
  • 2.5..13 V = pulse low
V Pulse is 3.3V, 5V and 12V logic compatible. Pulse high outputs current defined by setpoint, pulse low outputs current 0.035*setpoint.

Mechanical & environmental

Property Value Units Remarks
Dimensions 94×77.5×17 mm W×H×D
Operating temperature range -40..85 °C Non condensing. Output rating may derate at high temperature without forced convection
Reliability MTBF 1.5 106 Hrs Per Bellcore TR-332 50% stress, Tamb = 40 °C
ESD protection Exceeds ESD Protection to IEC61000-4-2 Level 4, ±12 kV discharge All I/O lines

Literature


In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.