This page supports semantic in-text annotations (e.g. "[[Is specified as::World Heritage Site]]") to build structured and queryable content provided by Semantic MediaWiki. For a comprehensive description on how to use annotations or the #ask parser function, please have a look at the getting started, in-text annotation, or inline queries help page.

Latest revision Your text
Line 1: Line 1:
{{ArgonManualNav}}All [[SimpleMotion V2]] compatible devices have a settable address that identifies the device on a multidrop communication bus. Each device sharing the same bus must have an unique address number to make error free communication possible. For example configuring bus address is required to establish a connection with [[Granity]] software.
+
All [[SimpleMotion V2]] compatible devices have a settable address that identifies the device on a multidrop communication bus. Each device sharing the same bus must have an unique address number to make error free communication possible. For example configuring bus address is required to establish a connection with [[Granity]] software.
 
+
==Setting bus address==
When accessing drive through [[SimpleMotion V2]] bus, each device in the bus should be assigned to different address between 1 to 32. Device address is a sum of hardware setting and software parameter {{param|SMO}} (IONI only). The address of device is determined at the moment of logic voltage power on and will become by sum of hardware setting and SMO.
+
The method of how address is set depends on device hardware implementation. This chapter lists methods for Granite Devices products.
 
+
 
===Argon===
 
===Argon===
 
[[File:Dipswitch.png|thumb|DIP switch of Argon. In this case the DIP has value 01001.]]
 
[[File:Dipswitch.png|thumb|DIP switch of Argon. In this case the DIP has value 01001.]]
Line 76: Line 75:
 
|-
 
|-
 
|}
 
|}
===Ioni/Ionicube===
 
When chaining multiple [[IONICUBE 1X]] motherboards (where all of them have address 1), it is necessary to utilize software parameter {{param|SMO}}. Procedure for setting unique address for each device with SMO:
 
 
#Disconnect or unpower all other devices that the ones with already unique address (i.e. have only one IONICUBE connected to SM bus, or powered on)
 
#Connect to drive with Granity
 
#Adjust SMO parameter value so that device will receive a desired bus address. I.e. if using IONICUBE 1X, set SMO values 0, 1, 2, 3 to the different drives (drive addresses will become 1, 2, 3, 4). Or when IONICUBE (4 axis) is being used, set SMO values of drives on the first board 0, second board 4, third 8 etc (drive addresses will become 1 - 12).
 
#Save settings, disconnect and repeat the procedure for all drives.
 
 
Same goes for chaining multiple [[IONICUBE]] 4 axis boards. However as base addresses of the drives on 4 axis boards are 1, 2, 3 and 4, one needs to increment SMO parameter by 4 on each chained IONICUBE. I.e. all the drives on first board should have SMO=0, the second SMO=4 and the third SMO=8 etc.
 
{{info|For instructions of setting address of IONI in custom motherboard designs, see [[IONI connector pinout]].}}
 
  
 
==Bus termination==
 
==Bus termination==
Line 95: Line 84:
 
If an E-stop button is connected with RJ45 cable after the last device, a bus '''stub''' is formed. Stub must not be longer than 30 cm or 1 foot to ensure reliable bus operation.
 
If an E-stop button is connected with RJ45 cable after the last device, a bus '''stub''' is formed. Stub must not be longer than 30 cm or 1 foot to ensure reliable bus operation.
  
Methods to eliminate the stub on [[SimpleMotion V2 port]] cable E-stop cable if longer than 30cm E-stop cable is needed:
+
Methods to eliminate the stub on E-stop cable if longer than 30cm E-stop cable is needed:
*Cut the RS485_A and RS485_B wires from the cable near connector, this ends the RS485 bus next to connector and minimizes stub
+
*Cut the A and B wires from the cable near connector or leave only the E-stop & enable button wires and GND left
*Alternatively, connect termination resistor at end of RS485_A and RS485_B wires and set DIP switch termination off
+
*Alternatively, connect termination resistor at end of A and B pair and set DIP switch termination off
  
 
==Troubleshooting==
 
==Troubleshooting==
Line 104: Line 93:
 
*If termination is missing or is present multiple times
 
*If termination is missing or is present multiple times
 
*If bus stub is too long
 
*If bus stub is too long
 
{{next|[[Argon user guide/Wiring]]}}
 
 
[[Category:Argon_user_guide]]
 
[[Category:IONI_user_guide]]
 
[[Category:IONICUBE]]
 

Please note that all contributions to Granite Devices Knowledge Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Granite Devices Knowledge Wiki:Copyrights for details). Do not submit copyrighted work without permission!

Select categories:

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)