− | This page lists parameters that [[Granity]] software reads/writes for drives. | + | This page lists parameters that [[Granity]] software reads/writes for drives in order to configure drives. |
− | + | The first column represents parameter number. On [[SimpleMotion library]], search parameter nubmer simplemotion_defs.h to find the human readable version of the parameter number (i.e. parameter 490 is defined as macro SMP_TORQUE_LPF_BANDWIDTH). | |
− | + | {{info|This list is work in progress and may lack important informatiaon. It also lacks some run-time (non-saved) parameters such as SMP_SYSTEM_CONTROL that can be used for example to zero feedback & setpoint position. For more info, refer to simplemotion_defs.h and SimpleMotion example applications provided.}} | |
{| class="wikitable" | {| class="wikitable" | ||
Line 125: | Line 125: | ||
[[Category:Lists]] | [[Category:Lists]] | ||
+ | [[Category:Granity_parameters]] | ||
+ | [[Category:SimpleMotion]] | ||
[[Category:Work_in_progress_pages]] | [[Category:Work_in_progress_pages]] |
Latest revision as of 14:44, 9 December 2016
This page lists parameters that Granity software reads/writes for drives in order to configure drives.
The first column represents parameter number. On SimpleMotion library, search parameter nubmer simplemotion_defs.h to find the human readable version of the parameter number (i.e. parameter 490 is defined as macro SMP_TORQUE_LPF_BANDWIDTH).
This list is work in progress and may lack important informatiaon. It also lacks some run-time (non-saved) parameters such as SMP_SYSTEM_CONTROL that can be used for example to zero feedback & setpoint position. For more info, refer to simplemotion_defs.h and SimpleMotion example applications provided. |
Parameter address | Granity GUI name | GUI scaling factor | Read only | Available in device models | Not in motor modes |
---|---|---|---|---|---|
14 | SimpleMotion bus address offsetSMO | 1 | 0 | Ioni,Ioni Pro,Atomi,OEM Drive | |
200 | Velocity I gainKVI | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
201 | Position P gainKPP | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
202 | Velocity P gainKVP | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
220 | Velocity feed-forward gainVFF | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
221 | Acceleration feed-forward gainAFF | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
222 | Position feed-forward gainPFF | 10.24 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
240 | NOTCHFILT | 1 | 0 | Ioni Pro | |
241 | Damping effectTED | 100 | 0 | Ioni Pro | |
242 | Friction effectTEF | 100 | 0 | Ioni Pro | |
243 | Inertia effectTEI | 100 | 0 | Ioni Pro | |
405 | Coil resistanceMR | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
406 | Coil inductanceML | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
410 | Continuous current limitMCC | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
411 | Peak current limitMMC | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
415 | Motor current limit during homingHMT | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
421 | Over current toleranceFOC | 16.6667 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
424 | Cogging compensation functionTRF1 | 1 | 0 | Ioni Pro,OEM Drive | |
425 | Cogging compensation currentTRA1 | 1000 | 0 | Ioni Pro,OEM Drive | |
426 | Torque ripple compensation functionTRF2 | 1 | 0 | Ioni Pro,OEM Drive | |
427 | Torque ripple compensation amplitudeTRA2 | 10.24 | 0 | Ioni Pro,OEM Drive | |
430 | Thermal time constantMTC | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
490 | Torque bandwidth limitTBW | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
491 | Axis scaleAXS | 100000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
492 | Axis type & unitsAXT | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
493 | Feedback deviceFBD | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
495 | Goal faults filter timeFFT | 2500 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
496 | Over speed faultFEV | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
498 | Limit switch functionLSF | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
555 | Position tracking error thresholdFPT | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
556 | Velocity tracking error thresholdFVT | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
557 | Error recovery velocityCRV | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
558 | Motor typeMT | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
559 | Control modeCM | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
560 | Setpoint multiplierMUL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
561 | Setpoint dividerDIV | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
562 | Setpoint inputCRI | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
563 | Setpoint offset nullingCAO | 163.84 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
565 | Feedback device resolutionFBR | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
566 | Pole countMPC | 0.5 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
568 | Motion fault thresholdFMO | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
569 | Over voltage fault thresholdFOV | 100 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
570 | Under voltage fault thresholdFUV | 100 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
571 | Maximum peak powerMPP | 1 | 0 | Ioni Pro | Stepper |
572 | Maximum speedMMS | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
573 | Electrical interfaceCEI | 1 | 0 | Ioni,Ioni Pro | |
800 | Acceleration limitCAL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
802 | Velocity limitCVL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
803 | Homing acceleration limitHMA | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
804 | Homing velocity limitHMV | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
808 | Hard stop detection thresholdHMH | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
823 | Offset move after homingHMF | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
835 | Position soft high limitHHL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
836 | Position soft low limitHLL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
910 | Mech brake release delayBER | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
911 | Mech brake engage delayBED | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
912 | Dynamic braking decelerationBDD | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive |