Line 38: | Line 38: | ||
== Wiring SSI encoder == | == Wiring SSI encoder == | ||
Wiring of SSI depends on the variant of SSI protocol present. | Wiring of SSI depends on the variant of SSI protocol present. | ||
+ | ===SSI encoder=== | ||
+ | Typical SSI encoder has differential signal lines and a supply voltage lines: | ||
+ | * Power supply lines (2 wires) | ||
+ | * Clock input (2 wires) | ||
+ | * Data output (2 wires) | ||
+ | Connection to IONI Pro drive by following table: | ||
+ | {| class="wikitable" | ||
+ | !BiSS wire | ||
+ | !IONI drive pin | ||
+ | !IONICUBE D-Sub 15 pin number | ||
+ | !Remarks | ||
+ | |- | ||
+ | |Cable shield | ||
+ | | | ||
+ | |Connector shell | ||
+ | | | ||
+ | |- | ||
+ | |GND | ||
+ | |GND | ||
+ | |10 | ||
+ | | | ||
+ | |- | ||
+ | |5V input | ||
+ | | | ||
+ | |9 | ||
+ | |Pin 9 is 5V supply output from IONICUBE to encoder | ||
+ | |- | ||
+ | |Clock+ | ||
+ | |GPI2 | ||
+ | |12 | ||
+ | | | ||
+ | |- | ||
+ | |Clock- | ||
+ | |GPI3 | ||
+ | |11 | ||
+ | | | ||
+ | |- | ||
+ | |Data+ | ||
+ | |C+ | ||
+ | |15 | ||
+ | | | ||
+ | |- | ||
+ | |Data- | ||
+ | |C- | ||
+ | |14 | ||
+ | | | ||
+ | |} | ||
+ | |||
+ | {{info|Cable termination resistors may be necessary for reliable operation, for more details, see [[Terminating differential encoder lines]].}} | ||
+ | |||
===AMS SSI encoder chips=== | ===AMS SSI encoder chips=== | ||
[http://ams.com/eng AMS] SSI encoders are wired following way to IONI encoder connector: | [http://ams.com/eng AMS] SSI encoders are wired following way to IONI encoder connector: |
Revision as of 22:04, 9 May 2017
SSI (Synchronous Serial Interface) is a digital protocol used by many encoder feedback device manufacturers. IONI Pro servo drive supports SSI encoders starting from firmware version 1.6.1.
Contents
[hide]SSI support details
As SSI is loosely defined standard, drive's SSI support may not cover all possible variations of the protocol. The following characteristics are supported:
- Read clock 1.5-2 MHz
- Strectched first clock for slower encoders
- Multiturn & singleturn readout
- Multiturn resolution from 0-16 bits
- Singleturn resolution 4-32 bits
- Sum of MT+ST resolutions must be between 4 and 32 bits
- Binary and Gray code support
Current firmware version limitations:
- No absolute encoder information is utilized, motor still needs to do Phasing a.k.a. phase search and Homing to get absolute operation.
List of tested SSI encoders:
Manufacturer | Model | Notes | Test result |
---|---|---|---|
AMS | AS5311 | 12 bit magnetic encoders | All OK |
RLS | Orbis | 14 bits absolute | All OK |
SICK | TTK70-AXA0-K02 | 24 bits absolute, gray code | All OK |
Wiring SSI encoder
Wiring of SSI depends on the variant of SSI protocol present.
SSI encoder
Typical SSI encoder has differential signal lines and a supply voltage lines:
- Power supply lines (2 wires)
- Clock input (2 wires)
- Data output (2 wires)
Connection to IONI Pro drive by following table:
BiSS wire | IONI drive pin | IONICUBE D-Sub 15 pin number | Remarks |
---|---|---|---|
Cable shield | Connector shell | ||
GND | GND | 10 | |
5V input | 9 | Pin 9 is 5V supply output from IONICUBE to encoder | |
Clock+ | GPI2 | 12 | |
Clock- | GPI3 | 11 | |
Data+ | C+ | 15 | |
Data- | C- | 14 |
![]() | Cable termination resistors may be necessary for reliable operation, for more details, see Terminating differential encoder lines. |
AMS SSI encoder chips
AMS SSI encoders are wired following way to IONI encoder connector:
AMS wire | IONI drive pin | IONICUBE D-Sub 15 pin number | Remarks |
---|---|---|---|
VSS (Ground) | GND | 10 | |
VDD5V (5V input) | 9 | Pin 9 is 5V supply output from IONICUBE to encoder | |
CLK | GPI3 | 11 | |
CSn | GPI2 | 12 | |
DO | GPI1 | 13 |
Refer to IONI & IONICUBE user guide for more info on wiring encoders.
Configuration
To configure SSI, use Granity version 1.11.1 or later. Configuration steps:
- Find out encoder MT and ST resolutions from encoder manufacturer's data sheet
- Select Serial data encoder from Feedback deviceFBD
- Select SSI type from Serial encoder typeFBS
- Set number of MT and ST bits into parameters Single-turn bitsFBST and Multi-turn bitsFBMT. If MT not specified in encoder data sheet, set it zero.