Difference between revisions of "Device connection troubleshooting"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(Created page with "This article helps finding cure for connection problems between PC and drive. ==Granity== Granity requires following to establish connection: *Compatible RS485 adapter, such a...") |
(→Granity) |
||
Line 4: | Line 4: | ||
*Compatible RS485 adapter, such as [[SimpleMotion V2 USB Adapter]] | *Compatible RS485 adapter, such as [[SimpleMotion V2 USB Adapter]] | ||
*SimpleMotion V2 compliant drive, such as Argon | *SimpleMotion V2 compliant drive, such as Argon | ||
− | * | + | *SimpleMotion V2 calbing with termination |
− | *Correct bus address setting on all devices in the SM V2 bus | + | *Correct bus address setting on all devices in the SM V2 bus, see [[Setting device bus address]] |
+ | ===Typical errors=== | ||
+ | *Bus address conflicting between devices (two or more devices set to same address) | ||
+ | *Missing bus termination | ||
+ | *Device has an error state, see led indicators | ||
[[Category:Troubleshooting]] | [[Category:Troubleshooting]] | ||
[[Category:Argon]] | [[Category:Argon]] | ||
[[Category:Granity]] | [[Category:Granity]] |
Revision as of 16:00, 2 March 2013
This article helps finding cure for connection problems between PC and drive.
Granity
Granity requires following to establish connection:
- Compatible RS485 adapter, such as SimpleMotion V2 USB Adapter
- SimpleMotion V2 compliant drive, such as Argon
- SimpleMotion V2 calbing with termination
- Correct bus address setting on all devices in the SM V2 bus, see Setting device bus address
Typical errors
- Bus address conflicting between devices (two or more devices set to same address)
- Missing bus termination
- Device has an error state, see led indicators