Difference between revisions of "IONI firmware releases"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(→Releases) |
|||
Line 51: | Line 51: | ||
**Improve [[Phasing a.k.a. phase search]] algorithm speed | **Improve [[Phasing a.k.a. phase search]] algorithm speed | ||
|| || Medium | || || Medium | ||
+ | |- | ||
+ | | 1.1.0 [[Media:IONIFWpackage1.1.0.gdf|download]] || 15.4.2015|| 1060 || | ||
+ | *New features | ||
+ | **Added ''Measure motor resistance and inductance'' function. See [[Measure motor resistance and inductance in Granity]]. | ||
+ | *Fixes | ||
+ | **Fix incorrect (too high) current scale for Brush DC motors | ||
+ | || The new feature requires Granity V 1.6.0 || Medium (High for DC motor users) | ||
|} | |} | ||
Revision as of 10:51, 15 April 2015
This page lists the official firmware releases of the IONI Servo Drive and the change log.
Upgrading firmware
Read instructions from Granity user guide/Uploading a firmware.
Releases
- Glossary
- Firmware release version - a firmware file with .gdf name extension that contains the firmware firmware
- Version code - the version shown in Granity
- Change log - the list of changes made since the previous package version.
- Remarks - Notes
Firmware release version | Date | Version code | Change log | Remarks | Importance |
---|---|---|---|---|---|
1.0.0 | 15.3.2015 | 1050 |
|
||
1.0.1 | 19.3.2015 | 1052 |
|
Medium | |
1.0.2 | 11.4.2015 | 1054 |
|
Important upgrade due to overcurrent protection fix and phasing current calcuation fix. | Critical |
1.0.3 | 12.4.2015 | 1056 |
|
Medium | |
1.0.4 download | 13.4.2015 | 1058 |
|
Medium | |
1.1.0 download | 15.4.2015 | 1060 |
|
The new feature requires Granity V 1.6.0 | Medium (High for DC motor users) |
Known bugs & limitations
Bugs that are known in the latest FW revision:
- Setpoint smoothing does not have effect in velocity or torque modes (only position mode)