Difference between revisions of "SimuCUBE technical specifications"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(Tag: VisualEditor) |
|||
Line 3: | Line 3: | ||
== Mechanical == | == Mechanical == | ||
− | + | [[File:Simucube dimensions.png|thumb|Dimension drawing]] | |
+ | {| class="wikitable" | ||
+ | !Dimension | ||
+ | !Length | ||
+ | |- | ||
+ | |Width | ||
+ | |160 mm | ||
+ | |- | ||
+ | |Depth | ||
+ | |87.5 mm | ||
+ | |- | ||
+ | |Height | ||
+ | |< 50 mm (with IONI drive inserted) | ||
+ | |} | ||
− | == | + | == Environmental == |
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 16: | Line 29: | ||
| Humidity || 0-95 non-condensing || % | | Humidity || 0-95 non-condensing || % | ||
|} | |} | ||
+ | Note: on board IONI drive will require forced air flow cooling above 7 A output drive current. | ||
== Power supply == | == Power supply == | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
− | + | ! Input voltage !! Input current when idle !! Input current max | |
|- | |- | ||
− | | | + | | 24 - 55 VDC<sup>1</sup> || Typically < 0.4 A |
+ | |Depends on power driven to motor. Up to about 25 A peak consumption is possible. In typical cases 10A @ 48V is sufficient supply. | ||
|} | |} | ||
− | + | Notes: | |
+ | * SimuCUBE has an input diode for reverse input voltage protection | ||
+ | * Switching mode power supply (SMPS) and linear transformer based power supplies are directly suitable | ||
− | + | == Electrical == | |
+ | All back face I/O connector pins of SimuCUBE are ESD protected. | ||
+ | == Motor control == | ||
+ | SimuCUBE motor control is based on a [[IONI Servo & Stepper Drive]] that plugs on the provided socket. All motor control specifications are identical to IONI drive specifications. Refer to [[IONI specifications]] for details about: | ||
+ | * Output current ratings | ||
+ | * Supported [[Feedback devices]] | ||
+ | * Heat dissipation & cooling | ||
+ | * Fault protections | ||
{{next|[[SimuCUBE user guide/SimuCUBE pinout|Pinout]]}} | {{next|[[SimuCUBE user guide/SimuCUBE pinout|Pinout]]}} | ||
[[Category:SimuCUBE]] | [[Category:SimuCUBE]] | ||
[[Category:SimuCUBE_user_guide]] | [[Category:SimuCUBE_user_guide]] |
Revision as of 23:04, 28 June 2016
Electrical
Please refer to IONI specifications for detailed information of the different IONI servo drive models.
Mechanical
Dimension | Length |
---|---|
Width | 160 mm |
Depth | 87.5 mm |
Height | < 50 mm (with IONI drive inserted) |
Environmental
Property | Value | Units |
---|---|---|
Operating temperature | 10-70 | °C |
Storage temperature | -30-90 | °C |
Humidity | 0-95 non-condensing | % |
Note: on board IONI drive will require forced air flow cooling above 7 A output drive current.
Power supply
Input voltage | Input current when idle | Input current max |
---|---|---|
24 - 55 VDC1 | Typically < 0.4 A | Depends on power driven to motor. Up to about 25 A peak consumption is possible. In typical cases 10A @ 48V is sufficient supply. |
Notes:
- SimuCUBE has an input diode for reverse input voltage protection
- Switching mode power supply (SMPS) and linear transformer based power supplies are directly suitable
Electrical
All back face I/O connector pins of SimuCUBE are ESD protected.
Motor control
SimuCUBE motor control is based on a IONI Servo & Stepper Drive that plugs on the provided socket. All motor control specifications are identical to IONI drive specifications. Refer to IONI specifications for details about:
- Output current ratings
- Supported Feedback devices
- Heat dissipation & cooling
- Fault protections
Read next |