Difference between revisions of "SimuCUBE technical specifications"
From Granite Devices Knowledge Wiki
| [checked revision] | [checked revision] |
(Tag: VisualEditor) |
|||
| Line 3: | Line 3: | ||
== Mechanical == | == Mechanical == | ||
| − | + | [[File:Simucube dimensions.png|thumb|Dimension drawing]] | |
| + | {| class="wikitable" | ||
| + | !Dimension | ||
| + | !Length | ||
| + | |- | ||
| + | |Width | ||
| + | |160 mm | ||
| + | |- | ||
| + | |Depth | ||
| + | |87.5 mm | ||
| + | |- | ||
| + | |Height | ||
| + | |< 50 mm (with IONI drive inserted) | ||
| + | |} | ||
| − | == | + | == Environmental == |
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
| Line 16: | Line 29: | ||
| Humidity || 0-95 non-condensing || % | | Humidity || 0-95 non-condensing || % | ||
|} | |} | ||
| + | Note: on board IONI drive will require forced air flow cooling above 7 A output drive current. | ||
== Power supply == | == Power supply == | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
| − | + | ! Input voltage !! Input current when idle !! Input current max | |
|- | |- | ||
| − | | | + | | 24 - 55 VDC<sup>1</sup> || Typically < 0.4 A |
| + | |Depends on power driven to motor. Up to about 25 A peak consumption is possible. In typical cases 10A @ 48V is sufficient supply. | ||
|} | |} | ||
| − | + | Notes: | |
| + | * SimuCUBE has an input diode for reverse input voltage protection | ||
| + | * Switching mode power supply (SMPS) and linear transformer based power supplies are directly suitable | ||
| − | + | == Electrical == | |
| + | All back face I/O connector pins of SimuCUBE are ESD protected. | ||
| + | == Motor control == | ||
| + | SimuCUBE motor control is based on a [[IONI Servo & Stepper Drive]] that plugs on the provided socket. All motor control specifications are identical to IONI drive specifications. Refer to [[IONI specifications]] for details about: | ||
| + | * Output current ratings | ||
| + | * Supported [[Feedback devices]] | ||
| + | * Heat dissipation & cooling | ||
| + | * Fault protections | ||
{{next|[[SimuCUBE user guide/SimuCUBE pinout|Pinout]]}} | {{next|[[SimuCUBE user guide/SimuCUBE pinout|Pinout]]}} | ||
[[Category:SimuCUBE]] | [[Category:SimuCUBE]] | ||
[[Category:SimuCUBE_user_guide]] | [[Category:SimuCUBE_user_guide]] | ||
Revision as of 23:04, 28 June 2016
Electrical
Please refer to IONI specifications for detailed information of the different IONI servo drive models.
Mechanical
| Dimension | Length |
|---|---|
| Width | 160 mm |
| Depth | 87.5 mm |
| Height | < 50 mm (with IONI drive inserted) |
Environmental
| Property | Value | Units |
|---|---|---|
| Operating temperature | 10-70 | °C |
| Storage temperature | -30-90 | °C |
| Humidity | 0-95 non-condensing | % |
Note: on board IONI drive will require forced air flow cooling above 7 A output drive current.
Power supply
| Input voltage | Input current when idle | Input current max |
|---|---|---|
| 24 - 55 VDC1 | Typically < 0.4 A | Depends on power driven to motor. Up to about 25 A peak consumption is possible. In typical cases 10A @ 48V is sufficient supply. |
Notes:
- SimuCUBE has an input diode for reverse input voltage protection
- Switching mode power supply (SMPS) and linear transformer based power supplies are directly suitable
Electrical
All back face I/O connector pins of SimuCUBE are ESD protected.
Motor control
SimuCUBE motor control is based on a IONI Servo & Stepper Drive that plugs on the provided socket. All motor control specifications are identical to IONI drive specifications. Refer to IONI specifications for details about:
- Output current ratings
- Supported Feedback devices
- Heat dissipation & cooling
- Fault protections
| Read next |