===Device stuck at startup=== | ===Device stuck at startup=== | ||
Problem: Device stuck in "Waiting for drive to get ready" and does not start correctly. The E-stop button status follows the real e-stop button. | Problem: Device stuck in "Waiting for drive to get ready" and does not start correctly. The E-stop button status follows the real e-stop button. | ||
− | + | Possible cause: Internal cable for the power button is placed in a bad/sensitive location inside the device. | |
Note: This service instruction is only applicable to Simucube 2 Sport and Pro R1 units (Pro with 2 power supplies) that were produced before August 2020. R1 units have a rocker switch near the one of the rear corners as a power switch, where as R2 units have a on/off toggle switch near the center of the back plate. | Note: This service instruction is only applicable to Simucube 2 Sport and Pro R1 units (Pro with 2 power supplies) that were produced before August 2020. R1 units have a rocker switch near the one of the rear corners as a power switch, where as R2 units have a on/off toggle switch near the center of the back plate. | ||
* {{dlfile|SC2_Sport_&_Pro_R1_power_button_wire_check.pdf|Simucube 2 Sport/Pro R1 power button wire check (PDF)}} | * {{dlfile|SC2_Sport_&_Pro_R1_power_button_wire_check.pdf|Simucube 2 Sport/Pro R1 power button wire check (PDF)}} |
Revision as of 20:19, 25 January 2021
This page lists all officially published documentation of Simucube 2 systems. The main Simucube 2 product website is at https:///www.simucu.be
Contents
Software
see Simucube 2 True Drive software releases
User manuals
Service manuals
Note: Review the instructions carefully and only perform service procedures if you feel comfortable performing them. Your reseller will always help if necessary.
Quick release slipping
Problem: Wheel/quick release is slipping and center point is changing. Cause: The conical shaft adapter is slipping. This affected many of the very first produced Simucube 2 units in May 2019.
Device stuck at startup
Problem: Device stuck in "Waiting for drive to get ready" and does not start correctly. The E-stop button status follows the real e-stop button. Possible cause: Internal cable for the power button is placed in a bad/sensitive location inside the device. Note: This service instruction is only applicable to Simucube 2 Sport and Pro R1 units (Pro with 2 power supplies) that were produced before August 2020. R1 units have a rocker switch near the one of the rear corners as a power switch, where as R2 units have a on/off toggle switch near the center of the back plate.
Antenna connector / cable issues
Problem: The external antenna connector is loose. Cause: Loose antenna connector. Note: Do not spin the antenna connector to not cause it to wind up and break.
- Simucube 2 Sport/Pro antenna connection retighten instructions (PDF)
- Simucube 2 Ultimate antenna connector replacement / re-tightening guide (PDF)
Problem: Spinning antenna connector has caused the internal antenna cable to break. Solution: Replace the antenna connector&cable assembly. Contact your reseller for spare parts.
- Simucube 2 Sport/Pro R1 antenna connector replacement guide (PDF)
- Simucube 2 Sport/Pro R2 antenna connector replacement guide (PDF)