All SimpleMotion V2 compatible devices have a settable address that identifies the device on a multidrop communication bus. Each device on the sharint the same bus must have an unique address number to make error free communication possible. For example configuring bus address is required to establish a connection with Granity software.

If two or more devices are incorrectly set to have same address, packet collisions will happen in the bus causing communication failures.

Setting bus address various devices

The method of how address is set depends on device hardware implementation. This chapter lists methods for Granite Devices products.

Argon

DIP switch of Argon. In this case the DIP has value 01001.

Argon (servo drive) has a 5 channel DIP switch that sets the address.

Address Termination on DIP switch setting (switches from 1 to 5)
255 (firmware upgrade mode) Off 00000
255 (firmware upgrade mode) On 00001
1 Off 00010
1 On 00011
2 Off 00100
2 On 00101
3 Off 00110
3 On 00111
4 Off 01000
4 On 01001
5 Off 01010
5 On 01011
6 Off 01100
6 On 01101
7 Off 01110
7 On 01111
8 Off 10000
8 On 10001
9 Off 10010
9 On 10011
10 Off 10100
10 On 10101
11 Off 10110
11 On 10111
12 Off 11000
12 On 11001
13 Off 11010
13 On 11011
14 Off 11100
14 On 11101
15 Off 11110
15 On 11111