Argon firmware releases

From Granite Devices Knowledge Wiki
Revision as of 19:10, 12 February 2014 by Tero K (Talk | contribs) (Known bugs)


Jump to: navigation, search

This page lists the official firmware releases of the Argon (servo drive) and the change log.

Glossary
  • Firmware package - a firmware file with .gdf name extension that contains combined firmware for Argon I/O side processor and GraniteCore processor
  • I/O side - the I/O side processor of Argon. The source code of this processor is open source.
  • GraniteCore - the motion control processor inside the Argon.
  • Change log - the list of changes made since the previous package version.
  • Remarks - Notes
Firmware package version Date I/O side version GraniteCore version Change log Remarks Importance
0.9.0 1.7.2013 1000 1000 Development version Shipped with the first production batch
1.0.0 1.9.2013 1000 1005 Initial official release A requirement for Granity 1.0.0
1.0.1 3.9.2013 1000 1006
  • Add STAT_STO_ACTIVE statusbit
  • Incremental setpoint change now changes also absolute setpoint readout value
A requirement for Granity 1.0.1 Functional
1.0.2 18.9.2013 1001 1007

New features:

  • Analog in setpoint now has direction input to support 0-10V sources with direction signal (in addition to standard +/-10V)
  • New AC/BLDC motor phasing algorithm:
    • Improved operation when axis is heavy to move
    • Phasing now supports limit switches. Now it's possible to use Hall-sensorless phasing when axis lies at the end of travel or if axis is vertical and pulled down by gravity. Requires limit switches on axis and configuring LFS to other than Do nothing.
  • Feature to invert the polarity of motor positive/negative direction. Parameter AXI on Granity.
  • Improved Dead-time distortion correction giving better servo stiffness

Bug fixes:

  • Hall sensor support fixed
  • Failure of phasing under high friction fixed
  • Toggling of general purpose input lines no longer clear faults in case of clear faults signal is constantly on while other signals change state
  • Limit switches now work properly in torque control mode

Adjustments:

  • Goal deviation default fault filter time reduced from 0.2 to 0.1 s
  • Space vector modulation code cleanup
  • Default motor direction is inverted compared to the earlier versions (tick AXI to set it same way it was before this version)

A requirement for Granity 1.0.2

Re-tuning may be necessary after upgrade!

Important and useful for most users, upgrade highly recommended
1.0.3 download 20.9.2013 1001 1008
  • Prevent drive damage in certain conditions (see remarks)
  • Activating STO2 now latches a Power stage forced off fault state requiring a clear faults command to return in normal operation
Usage of older firmware versions safe only if STO2 input has been permanently tied to 24 VDC. Critical
1.0.4 download 27.9.2013 1001 1009
  • Fix homing issue when index pulse was enabled (HMI) and AXI was unticked
Minor fix
1.1.0 download 6.11.2013 1002 1015
  • New features:
    • Add motor stopping & braking parameters: BDD and BED
    • Add BAP parameter to assist motor phasing on a vertical axis where gravity pulls axis down. May eliminate Hall sensor requirement on such axis.
    • Motor now returns to the position where it located at the moment of drive power-on (cancel the motion caused by phasing). Works in position & velocity modes.
  • Improvements:
    • Optimized torque efficiency on high electrical frequency motors
    • Follow error warning status & digital output now works also in velocity control mode in addition to position mode
    • Improve overcurrent protection setting FOC consistency
    • Changed the default FOV limit value from 350 to 365 VDC to avoid braking resistor heating when idling
  • Known bug: Sometimes Initialized state never goes on and also homing won't start in such case. Will be fixed in 1.1.1.
Adjusting the new parameters require Granity V1.1.0.

Re-adjusting FOC may be necessary.

New features. Overcurrent protection consistency improved.
1.1.1 download 7.11.2013 1004 1016
  • Fixes & adjustments:
    • Properly always sets Initialized state as true after drive is ready for operation
    • Now motor doesn't rotate to zero position in pulse & direction and quadrature setpoint source modes when Apply is clicked on Granity
Fixes & adjustments, not critical
1.2.0 download 10.12.2013 1005 1017
  • Improvements:
    • Servo control bandwidth increased due to lower position & velocity feedback latency
    • Motion jerks reduced/eliminated while drive is communicating through SimpleMotion V2 bus
  • Fixes & adjustments:
    • Corrected "Optimized torque efficiency on high electrical frequency motors" feature functionality of FW package 1.1.0 when AXI or FBI parameter was set to true.
    • Fix incorrectly displayed torque capture graph polarity when AXI was set
    • FOV maximum value increased from 375 to 382 VDC
In most cases servo velocity & position gains may now be set higher yielding higher motor stiffness.

Checking motor tuning recommended after upgrade.

Known bugs

Bugs that are known in the latest FW revision:

  • Drive may not complete initialization procedure if CRV value is set 0

In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.