SimpleMotion V2 communication link and Argon drives use RJ45 connectors and cables as physical connection standard.
RJ45 is well known from Ethernet connectors and same cables may be used with SimpleMotion wiring.
Contents
Electrical properties
SimpleMotion V2 uses RS485 electrical serial communication standard for all data transfer. Some main benefits of using RS485 are:
- Multidrop buses possible (up to 32 devices in single serial link)
- High reliability due to differential signaling
- High data rates and long cable lengths possible
- Easy to interface even from smallest microcontrollers with UART
- Low wire count, only 2 signal wires + ground needed
- Bidirectional data transfer (receive & transmit) in one wire pair
As default SimpleMotion V2 uses 460800 BPS bitrate and can deliver over 10 000 motion commands per second.
Use as E-stop & Enable input
In Argon drive, the same connector acts also as emergencecy stop or Safe torque off input. User may connect a e-stop button directly at the end of device chain to gain reliable stopping mechanism for all linked devices.
Wiring with SMV2BRK
The preferred method to wire STO and Enable signals to SM bus is to add a SMV2BRK break out board at the end of bus chain. SMV2BRK acts as RS485 termination resistor and a wire terminal for STO and Enable signals with easy interfacing to switches.
For commissioning of SMV2BRK, see it's dedicated SMV2BRK page.
Wiring with bare RJ45 cable
SimpleMotion V2 devices use pins 3, 6 and 8 (RS485_A,RS485_B and GND) for serial communication. If something interferes these lines, communication may fail or devices may be damaged. Before powering 24V to any of the pins, ensure that pins 3 and 6 are not connected to any external circuit. It's also highly recommended to use current limited 24V power source for initial tests to reduce risk of damage (0.15-0.3A limit). |
Connector pinout
Pin # | Signal name | Description | Electrical wiring |
---|---|---|---|
1 | STO2_24V | STO input 2 | Supply 24VDC in this pin referenced to GND to disable STO2. 1 |
2 | Reserved | Reserved for future use | Do not connect |
3 | RS485_A | RS485 signal A | RJ45 cable routes this between devices and SimpleMotion V2 USB adapter |
4 | STO1_24V | STO input 1 24V in | Supply 24VDC between STO1_24V and STO1_0V to disable STO1. STO1 inputs are floating and isolated from GND. 1, 2 |
5 | STO1_0V | STO input 1 0V in | |
6 | RS485_B | RS485 signal B | RJ45 cable routes this between devices and SimpleMotion V2 USB adapter |
7 | ENABLE_IN_24V | Drive enable control signal | Supply 24VDC in this pin referenced to GND to set drive in enabled state. |
8 | GND | Ground reference for: RS485, STO2 and ENABLE_IN | RJ45 cable routes this between devices and SimpleMotion V2 USB adapter. For enable & STO connect this to external 24V power supply ground. |
1) STO1 and STO2 are controlling two independent Safe torque off methods. Both must be supplied 24V simultaneously to enable torque to the motor.
2) STO1 has limited functionality on Argon if HV DC bus is shared between drives or external DC voltage is supplied. For more info, see Argon user guide/J4 connector wiring.
Even when RJ45 connector and cables are being used in Ethernet and SimpleMotion, these protocols are not electrically compatible. Never connect SimpleMotion device to Ethernet device. |
Don't use crossover cables in SimpleMotion V2 system |
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.