VSD-E/XE firmware releases
VSD-E and VSD-XE drives have two main operating modes: Evolution and DualDC. Evolution is an advanced single servo motor mode for AC, BLDC, brush DC and linear motors while DualDC converts drive to two-axis brush DC servo drive with reduced feature set. Factory default is the Evolution mode.
This page lists publicly released firmware files for VSD-E/XE.
Contents
Usage
Firmware files may be loaded to drive by using GDlfasher program that is supplied in DCtool & GDflasher package.
Configuration
Evolution firmware must be configured by using GDtool software and DualDC must be configured with DCtool software only. If you mix configuration software and firmware, re-flash firmware to the drive as wrong configuration tool might cause broken configuration and unexpected problems. Flashing firmware always resets all parameters to factory state.
Standard firmware
Evolution
Standard Evolution firmware version number 208. Download.
DualDC
Standard DualDC firmware version number 2004. Download.
Modified firmware files
These firmwares are modified from standard FW and haven't gone through as extensive testing as standard FW. However based on customer feedback, no problems are found.
Evolution
- Alternative 1
No error recovery motion and overcurrent fault tolerance adjustments. This firmware lets motor stand still after clear faults command is issued (standard behavior tries to drive motor back to commanded position). Also overcurrent tolerance has been increased to avoid overcurrent faults. Download.
- Alternative 2
Overcurrent fault tolerance adjustments. In this firmware overcurrent tolerance has been increased to avoid overcurrent faults. Download.
Using overcurrent fault tolerance adjusted firmware may render short circuit protection ineffective. If motor output is short circuited or loaded improperly, drive may be permamently damaged. Use only at own risk. Before use, verify that there is no short circuits and verify that drive works also with standard FW. |
DualDC
- Alternative 1
No error recovery motion. This firmware lets motor stand still after clear faults command is issued (standard behavior tries to drive motor back to commanded position). Download.
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.