IONICUBE connectors and pinouts
IONICUBE connectors
- X1
- Dual port RJ45 connector with SimpleMotion V2 interface. For pinout, seeSimpleMotion V2 port.
- X2
- 6 pin wire terminal for logic voltage supply, Safe torque off input, analog output and relay driver outputs.
- X3
- Two pin wire terminal for HV DC bus supply.
- X4
- Main control and setpoint signal port consisting Enable input signal, Fault output signal, pulse and direction/quadrature/PWM setpoint inputs and digital outputs for home switch status. X4 is directly wired to conform most common parallel port style pulse & direction CNC controllers.
- X5
- Second control and setpoint signal port. This port consists analog setpoint signal inputs and additional digital I/O.
- X6
- These are the feedback device connector for X (lower) and Y (upper) axis motors
- X7
- These are the power and holding brake output connector for X (lower) and Y (upper) axis motors
- X8
- These are the feedback device connector for Z (lower) and A (upper) axis motors
- X9
- These are the power and holding brake output connector for Z (lower) and A (upper) axis motors
- X10
- A connector for an optional external regenerative resistor. IONICUBE has on-board regenerative resistor that is sufficient for most installations.
- IONI_X, IONI_Y, IONI_Z, IONI_A
- Card-edge connectors for IONI drives
Before inserting or removing IONI drives from IONICUBE, remove all power from it and discharge it's capacitors. To discharge remaining energy (~voltage) from capacitors, short circuit GND to HV+ by a conductor and measure that there is no DC voltage left between GND and HV+ terminals. Even few volts left to HV DC bus is known to cause permanent damage to IONICUBE when drives are plugged. |
Front side connectors
Front side connectors consist X6, X7, X8 and X9. These connectors are the interface towards motors (motor power and feedback devices).
Names of power and feedback ports. I.e. X9A means upper floor connector of X9 and X9B the lower floor of X9. View from plug side of the board.
Legend
Color |
---|
Supply pin |
Input pin |
Output pin |
X7 and X9 pinout
These are the power output and holding brake output connector for motors
Pin number | Signal name | Usage |
---|---|---|
1 | GND | Ground for cable shield and an optional motor holding brake coil |
2 | PHASE1 | Motor phase 1 |
3 | PHASE2 | Motor phase 2 |
4 | PHASE3 | Motor phase 3 |
5 | PHASE4 | Motor phase 4 |
6 | BRAKE | 24V motor holding brake coil drive |
Motor & brake wiring schematics
An easy way to verify correctness of two phase stepper connection: unplug the 6 pin connector and then measure resistance between phases 1-2 and 3-4. Multimeter should show the same resistance for both cases (typically 0.1 - 5 ohms). Also when measuring between phases 1-3, 1-4, 2-3 and 2-4, the multimeter should indicate open circuit. |
X6 and X8 pinout
X6 and X8 are the feedback device connectors of motors
Pin # | Pin name | Electrical type (in most feedback device modes) | Alternate electrical type (in some feedback device modes) | Connection with various feedback devices |
---|---|---|---|---|
Shell | GND | Earth/case | Feedback cable shield | |
1 | HALL_W | Digital input W | Hall sensor input, phase W | |
2 | HALL_V | Digital input V | Hall sensor input, phase V | |
3 | HALL_U | Digital input U | Hall sensor input, phase U | |
4 | GND | Encoder supply ground | ||
5 | B- | Differential input B- | SinCos input B- | Quadrature encoder (B channel)/SinCos/serial encoder/resolver input |
6 | B+ | Differential input B+ | SinCos input B+ | |
7 | A- | Differential input A- | SinCos input A- | Quadrature encoder (A channel)/SinCos/serial encoder/resolver input |
8 | A+ | Differential input A+ | SinCos input A+ | |
9 | 5V_OUT | Encoder supply 5V output | Encoder power supply | |
10 | GND | Encoder supply ground | ||
11 | GPI3 | Axis negative direction end limit switch (optional) | Connect normally closed (NC) limit switch between this pin and GND pin | |
12 | GPI2 | Axis positive direction end limit switch (optional) | Connect normally closed (NC) limit switch between this pin and GND pin | |
13 | GPI1 | Axis home switch switch (optional) | Connect normally closed (NC) limit switch between this pin and GND pin | |
14 | C- | Differential input C- | Quadrature encoder index channel (Z channel)/serial encoder input | |
15 | C+ | Differential input C+ |
Examples of feedback device and switch wiring
In case of single-ended encoder, connect encoder's A, B, Z only to drive's A+, B+ and C+ and leave drive's A-, B- and C- unconnected. |
With differential Hall sensor (which provides U+, U-, V+, V-, W+ and W-, connect only sensor's U+, V+ and W+ to drive's HALL_U/V/W. |
Never connect sensor negative outputs (A-/B-/C-/U-/V-/W-) to GND. Connect them to drive's A-/B-/C- or leave unconnected. |
Feedback devices with differential signaling may use varying naming schemes of signal pairs. For example differential signal X (which contains two electrical wires) may be denoted as: X+ and X-, or X and \X or X and X. In this Wiki we mark them X+ and X-. Some Fanuc encoders have quadrature signals named as PCA, /PCA, PCB, /PCB, PCZ and /PCZ which are equivalent to A, B and Z signal pairs. |
Back side connectors
Never connect an Ethernet to X1. While it uses similar connector and cabling, it is electrically incompatible with Ethernet. Devices may be permanently damaged by mixing Ethernet and SimpleMotion V2. |
Do now wire SimpleMotion V2 ports with crossover RJ45 cables (see details). Always use straight/non-crossover patch cables. If unsure about what is the type of your RJ45 cable, don't use it. |
X2 pinout
X2 is 6 pin wire terminal for logic voltage supply, Safe torque off input, analog output and relay driver outputs.
Pin number | Signal name | Usage |
---|---|---|
1 | GND | Ground |
2 | 24V | 24V logic supply |
3 | STO | Safe torque off input (this pin also available in X1, as defined in SimpleMotion V2 port |
4 | VFD | 0-12V analog output where voltage level is proportional to PWM duty cycle on pin PWM on X4. PWM frequency must be between 100 and 10000 Hz. |
5 | RL1 | Relay coil driver output 1. When RLIN1 on X4 is logic high, RL1 is pulled to GND by an open collector circuit. When RLIN1 is low, RL1 is floating (max 24V). Connect a relay that has 24VDC coil between RL1 and 24V (same 24V that is supplied to IONICUBE). Output current rating is max 500 mA. |
6 | RL2 | Relay coil driver output 2. When RLIN2 on X4 is logic high, RL2 is pulled to GND by an open collector circuit. When RLIN1 is low, RL2 is floating (max 24V). Connect a relay that has 24VDC coil between RL2 and 24V (same 24V that is supplied to IONICUBE). Output current rating is max 500 mA. |
X3 pinout
X3 is two pin wire terminal for HV DC bus supply.
Pin number | Signal name | Usage |
---|---|---|
1 | GND | Ground |
2 | HV+ | Motor power supply, HV DC bus (see IONI drive voltage range spec) |
X4 pinout
X4 is main control and setpoint signal port consisting Enable input signal, Fault output signal, pulse and direction/quadrature/PWM setpoint inputs and digital outputs for home switch status. X4 is directly wired to conform most common parallel port style pulse & direction CNC controllers.
Pin number in header | Pin number in D25 cable | Signal name | Typical usage | Pin number in header | Pin number in D25 cable | Signal name | Typical usage | |
---|---|---|---|---|---|---|---|---|
1 | 1 | ENABLE | Enable all axis (with or without chargepump) | 2 | 14 | PWM | PWM input for VFD analog output | |
3 | 2 | HSIN1_X | Pulse/step input X | 4 | 15 | GPO4_A | Limit switch output A | |
5 | 3 | HSIN2_X | Direction input X | 6 | 16 | RLIN1 | Controls RL1 state | |
7 | 4 | HSIN1_Y | Pulse/step input Y | 8 | 17 | RLIN2 | Controls RL2 state | |
9 | 5 | HSIN2_Y | Direction input Y | 10 | 18 | GND | Ground | |
11 | 6 | HSIN1_Z | Pulse/step input Z | 12 | 19 | GND | ||
13 | 7 | HSIN2_Z | Direction input A | 14 | 20 | GND | ||
15 | 8 | HSIN1_A | Pulse/step input A | 16 | 21 | GND | ||
17 | 9 | HSIN2_A | Direction input A | 18 | 22 | GND | ||
19 | 10 | STOP_OUT | Fault on any axis or E-stop (active low) | 20 | 23 | GND | ||
21 | 11 | GPO4_X | Limit switch output X | 22 | 24 | GND | ||
23 | 12 | GPO4_Y | Limit switch output Y | 24 | 25 | GND | ||
25 | 13 | GPO4_Z | Limit switch output Z | 26 | N/A | Not connected |
Connect X4/X5 only to 3.3V or 5V logic systems. For 24V logic the use of IONICUBE 1X is recommended |
Alternative setpoint signals
Setpoint mode is selected by software with parameter Setpoint inputCRI and behavior is affected by parameters Setpoint smoothingCIS, Setpoint multiplierMUL, Setpoint dividerDIV, Setpoint offset nullingCAO and Enable direction inputCED.
Drive listens setpoint commands also always through SimpleMotion V2 interface regardess of Setpoint inputCRI paramter setting. |
Signal name | Function | Used for | Remarks |
---|---|---|---|
HSIN1 | High speed digital input 1 | Depending on setpoint mode, can be either:
| |
HSIN2 | High speed digital input 2 | Depending on setpoint mode, can be either:
| |
ANAIN- | Differential analog negative input | Used for analog setpoint mode | Setpoint voltage is the voltage difference between ANAIN+ and ANAIN- |
ANAIN+ | Differential analog positive input | Used for analog setpoint mode |
X5 pinout
X5 is a second control and setpoint signal port in addition to X4. This port consists analog setpoint signal inputs and additional digital I/O.
Pin number in header | Pin number in D25 cable | Signal name | Typical usage | Pin number in header | Pin number in D25 cable | Signal name | Typical usage | |
---|---|---|---|---|---|---|---|---|
1 | 1 | GND | 2 | 14 | +5V_OUT | 5V supply from IONICUBE ^2 | ||
3 | 2 | ANAIN-_X | +/-10V analog input X | 4 | 15 | ANAIN+_X | +/-10V analog input X | |
5 | 3 | ANAIN-_Y | +/-10V analog input Y | 6 | 16 | ANAIN+_Y | +/-10V analog input Y | |
7 | 4 | ANAIN-_Z | +/-10V analog input Z | 8 | 17 | ANAIN+_Z | +/-10V analog input Z | |
9 | 5 | ANAIN-_A | +/-10V analog input A | 10 | 18 | ANAIN+_A | +/-10V analog input A | |
11 | 6 | GPO1_X | For pin function, refer to IONI connector pinout | 12 | 19 | GPI4_X | For pin function, refer to IONI connector pinout | |
13 | 7 | GPO1_Y | 14 | 20 | GPI4_Y | |||
15 | 8 | GPO1_Z | 16 | 21 | GPI4_Z | |||
17 | 9 | GPO1_A | 18 | 22 | GPI4_A | |||
19 | 10 | GPO5_X | 20 | 23 | GPI5_X | |||
21 | 11 | GPO5_Y | 22 | 24 | GPI5_Y | |||
23 | 12 | GPO5_Z | 24 | 25 | GPI5_Z | |||
25 | 13 | GPO5_A | 26 | N/A | GPI5_A |
A typical connection with parallel port style CNC controller such as Mach3/Mach4/LinuxCNC. A 26 pin ribbon cable may be directly connected to PC parallel port or to equivalent pinout step/dir generator such as SmoothStepper.
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.