This page lists parameters that Granity software reads/writes for drives.
This list is work in progress and may lack important informatiaon |
The first column represents parameter number. On SimpleMotion library, search parameter nubmer simplemotion_defs.h to find the human readable version of the parameter number (i.e. parameter 490 is defined as macro SMP_TORQUE_LPF_BANDWIDTH).
Parameter address | Granity GUI name | GUI scaling factor | Read only | Available in device models | Not in motor modes |
---|---|---|---|---|---|
14 | SimpleMotion bus address offsetSMO | 1 | 0 | Ioni,Ioni Pro,Atomi,OEM Drive | |
200 | Velocity I gainKVI | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
201 | Position P gainKPP | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
202 | Velocity P gainKVP | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
220 | Velocity feed-forward gainVFF | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
221 | Acceleration feed-forward gainAFF | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
222 | Position feed-forward gainPFF | 10.24 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
240 | NOTCHFILT | 1 | 0 | Ioni Pro | |
241 | Damping effectTED | 100 | 0 | Ioni Pro | |
242 | Friction effectTEF | 100 | 0 | Ioni Pro | |
243 | Inertia effectTEI | 100 | 0 | Ioni Pro | |
405 | Coil resistanceMR | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
406 | Coil inductanceML | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
410 | Continuous current limitMCC | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
411 | Peak current limitMMC | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
415 | Motor current limit during homingHMT | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
421 | Over current toleranceFOC | 16.6667 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
424 | Cogging compensation functionTRF1 | 1 | 0 | Ioni Pro,OEM Drive | |
425 | Cogging compensation currentTRA1 | 1000 | 0 | Ioni Pro,OEM Drive | |
426 | Torque ripple compensation functionTRF2 | 1 | 0 | Ioni Pro,OEM Drive | |
427 | Torque ripple compensation amplitudeTRA2 | 10.24 | 0 | Ioni Pro,OEM Drive | |
430 | Thermal time constantMTC | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
490 | Torque bandwidth limitTBW | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
491 | Axis scaleAXS | 100000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
492 | Axis type & unitsAXT | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
493 | Feedback deviceFBD | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
495 | Goal faults filter timeFFT | 2500 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
496 | Over speed faultFEV | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
498 | Limit switch functionLSF | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
555 | Position tracking error thresholdFPT | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
556 | Velocity tracking error thresholdFVT | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
557 | Error recovery velocityCRV | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
558 | Motor typeMT | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
559 | Control modeCM | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
560 | Setpoint multiplierMUL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
561 | Setpoint dividerDIV | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
562 | Setpoint inputCRI | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
563 | Setpoint offset nullingCAO | 163.84 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
565 | Feedback device resolutionFBR | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
566 | Pole countMPC | 0.5 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
568 | Motion fault thresholdFMO | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
569 | Over voltage fault thresholdFOV | 100 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
570 | Under voltage fault thresholdFUV | 100 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
571 | Maximum peak powerMPP | 1 | 0 | Ioni Pro | Stepper |
572 | Maximum speedMMS | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
573 | Electrical interfaceCEI | 1 | 0 | Ioni,Ioni Pro | |
800 | Acceleration limitCAL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
802 | Velocity limitCVL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
803 | Homing acceleration limitHMA | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
804 | Homing velocity limitHMV | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
808 | Hard stop detection thresholdHMH | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
823 | Offset move after homingHMF | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
835 | Position soft high limitHHL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
836 | Position soft low limitHLL | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
910 | Mech brake release delayBER | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
911 | Mech brake engage delayBED | 1000 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive | |
912 | Dynamic braking decelerationBDD | 1 | 0 | Argon,Ioni,Ioni Pro,Atomi,Atomi Advanced,Atomi DeepStep,Atomi Pro,OEM Drive |
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.