Difference between revisions of "File:Argon wiring multiple.png"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
(Tero K uploaded a new version of "File:Argon wiring multiple.png")
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
+
{{caution|Using HV DC bus sharing via VP and VN terminals or supplying external DC voltage to them, renders the [[safe torque off]] STO1 input unusable because STO1 is based on by cutting the AC supply. In order to preserve STO1 functionality with DC bus sharing, the STO1 signal must be fed simultaneously to all DC bus sharing drives. If an external DC supply is used (no AC input to L & N), then STO1 will not operate.<br/><br/>STO1 will also be inoperable if DC voltage is supplied to L & N inputs instead of AC. With DC supply, STO1 ibput must be always powered as the internal relay may damage if STO1 used with DC supply. }}

Latest revision as of 11:00, 25 October 2013

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current19:29, 3 September 2013Thumbnail for version as of 19:29, 3 September 20131,854 × 1,306 (215 KB)Tero K (Talk | contribs)
  • You cannot overwrite this file.

Metadata