BiSS Interface is an open standard used by many encoder feedback device manufacturers. IONI Pro servo drive supports BiSS encoders starting from firmware version 1.6.0.
Contents
BiSS support details[edit | edit source]
As BiSS is quite wide standard supporting large number of different setups and device types, it is important to acknowledge the properties BiSS interface in GD drives. In current firmware, following properties apply:
- Support BiSS B and BiSS C devices
- Read of multi-turn (MT) and single-turn (SD) data from encoder
- Resolution
- Single-turn resolution from 6 to 30 bits (however, higher than 30 bit resolution is still compatible, lowest bits are just ignored)
- Multi-turn resolution from 0 to 16 bits
- The sum of ST+MT bits must be between 6 and 32 bits
- Error detection by the means of
- No response from encoder. Drive sets timeout or loss of connection error if encoder does not respond with a "start bit" in 20 µs.
- Bit transfer error occurred causing large position jump to trigger tracking error
- Clock rate 5.1 MHz
- Support utilizing absolute position information from the encoder
- To skip axis homing procedure
- To initialize rotary motor immediately (no Phasing needed)
Current firmware version limitations:
- No data CRC verification. Suggested workaround is to apply sensible tracking error limits.
- No daisy chaining encoders is supported. Only one encoder may be connected to a drive.
- No cable delay compensation implemented. Less than 5 meter cable is recommended.
List of tested BiSS encoders:[edit | edit source]
Manufacturer | Model | Notes | Test result |
---|---|---|---|
RLS | Orbis BR10DCA14B12BD00 | 14 bits absolute (no multiturn data) | All OK |
Hengstler | AD36/1219AF.0XBI0:5653 | 19 bits absolute encoder with 12 bits multi turn | All OK |
Renishaw | Resolute RL32BAS001C30F | 32 bits absolute encoder | All OK |
Baumer | EFL360 - BL6.2M6B.21000.4 | 21 bits absolute encoder (no multiturn data) | All OK |
If you have tested another kind of encoder, please help us to inform the community by letting us know your encoder model and result by dropping a message into Granite Devices support.
SimuCUBE supports BiSS encoder resolutions up to 21 bits (2M counts/rev). |
Wiring BiSS encoder[edit | edit source]
BiSS encoder typically has 6 mandatory wires consisting:
- Power supply lines (2 wires)
- Clock input (2 wires)
- Data output (2 wires)
Connection to IONI Pro drive by following table:
BiSS wire | IONI drive pin | IONICUBE D-Sub 15 pin number | Remarks |
---|---|---|---|
Cable shield | Connector shell | ||
GND | GND | 10 | |
5V input | 9 | Pin 9 is 5V supply output from IONICUBE to encoder | |
Clock+ / MA+ | GPI2 | 12 | |
Clock- / MA- | GPI3 | 11 | |
Data+ / SLO+ | C+ | 15 | |
Data- / SLO- | C- | 14 |
Refer to IONI & IONICUBE user guide for more info on wiring encoders.
Cable termination resistors may be necessary for reliable operation, for more details, see Terminating differential encoder lines. |
Configuration[edit | edit source]
To configure BiSS, use Granity version 1.11.0 or later. Configuration steps:
- Find out encoder MT and ST resolutions from encoder manufacturer's data sheet
- Select Serial data encoder from Feedback deviceFBD
- Select corresponding protocol (BiSS B, BiSS C) from Serial encoder typeFBS
- Set number of MT and ST bits into parameters Single-turn bitsFBST and Multi-turn bitsFBMT
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.